background image

 

the  main  controller  and  the  preset 
temperature in the room is not reached; 

10.

 

value of room temperature and edition of 
the preset room temperature; 

11.

 

prompting  to  clean  the  boiler 

  the 

symbol  reminds  to  perform  cleaning  the 
burner  and  to  empty  the  ash  pan 
(optional,  depending  on  the  software  of 
the main controller); 

12.

 

alarm 

 the symbol flashes when:  

-  an  alarm  occurred  in  the  main 
controller, 
-      there  is  no  radio  connection  with  the 
radio module,  
the symbol is constantly displayed when: 
-  notification  was  received  at  the  main 
controller (prompt), 
-  the  thermostat  is  not  paired  with  the 
radio module; 

13.

 

operating  status  of  the  burner 

  the 

symbol  is  displayed  only  when  the 
program  of  the  main  controller  with  the 
radio  module  is  fully  compatible,  in 
accordance with point 15.4. Visible flame 
symbol  means  that  the  burner  is 
currently  working  (it  is  burning),  while 
the  flame  symbol  with  OFF  means  that 
the  burner  has  been  turned  off  by  the 
user; 

14.

 

parameter editing symbol; 

15.

 

signaling  of  one  time  charging  of  the 
HUW container; 

16.

 

activated  parental  lock  -  unblocking 

occurs after holding the 

 button for 5 

seconds. 

10.

 

Thermostat settings 

9.1.

 

Edition of the preset temperature 

Pressing 

 or 

 brings to the check / edit 

of  the  preset  temperature  which  starts  to 
flash. 

 

The  first  press  causes  to  edit  the  current 
preset temperature, but does not change the 
value. Only another press changes the value. 
The  saving  and  exit  from  the  edition  takes 

place  after  pressing 

  button.  If  the 

change  of  the  preset  temperature  value  is 

not  confirmed  with  the 

  button,  then 

after  the  inactivity  time  of  5  seconds  the 
thermostat  will  exit  the  editing  menu, 
without  changing  the  preset  temperature 
value. The preset temperature value changes 

every  0,1

ºC. 

Note: holding 

 or 

button 

for  2  seconds  causes  a  fast,  cyclical  change 
of the parameter. 

9.2.

 

Edition of the operation modes 

Editing  the  operating  modes  is  enabled  by 

briefly  pressing  the 

  button,  then  the 

operating  modes  are  displayed,  with  the 
current operating mode flashing. 

 

 

The  operating  mode  is  changed  with 

  or 

  buttons.  The  saving  and  exit  from  the 

edition  takes  place  after  pressing  the 

 

button.  Exit  from  editing  the  operating 
modes  to  the  main  screen,  without  saving 
the change of the working mode, by pressing 
the A key for 2 seconds or after an idle time 

Summary of Contents for eSTER x40

Page 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Page 2: ......

Page 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Page 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Page 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Page 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Page 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Page 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Page 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Page 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Page 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Page 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Page 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Page 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Page 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Page 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Page 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: