background image

 

7.

 

Directive WEEE 2012/19/UE  

Purchased  product  is  designed  and  made  of 
materials of highest quality. 
The  product  meets  the  requirements  of  the 

Directive 2012/19/EU of 4 July 2012 on 
waste 

electrical 

and 

electronic 

equipment (WEEE)

, according to which it is 

marked  by  the  symbol  of  crossed-out 
wheeled  bin  (like  below),  meaning  that 
product is subjected to separate collection. 

 

Responsibilities  after  finishing  a  period  of 
using product: 

 

dispose  of  the  packaging  and  product  at 
the  end  of  their  period  of  use  in  an 
appropriate recycling facility,  

 

do  not  dispose  of  the  product  with  other 
unsorted waste,  

 

do not burn the product. 

By  adhering  obligations  of  waste  electrical 
and  electronic  equipment  controlled  disposal 
mentioned above, you avoid harmful.  

8.

 

The first start of the thermostat 

 

After  inserting  the  battery  into  the 
thermostat,  according  to  point  14.1 
and  electrical  connection  of  the 
ISM_xSMART  radio  module  to  the 
main  controller,  in  accordance  with 
point 15.5 it is necessary to perform 
the  thermostat  pairing  with  the 
radio  module,  as  described  in  point 
15.2. 

The  clock  synchronization  function  with  the 
main  controller  automatically  sets  the  clock 
in the thermostat. The  clock can also be set 
directly  in  the  thermostat  from  the  User 
menu (

P04

). 

 

The  change  of  time  in  the 
thermostat will also cause a change 
in  the  main  controller  and  the 
devices  connected  to  the  main 
controller. 

9.

 

Thermostat main screen 

 

Legend: 
1.

 

Operation modes: 

  - Schedule; 

 - Holiday; 

 - Comfortable;  

 - Economic;   

 - Antifreeze; 

Air

 

 Airing; 

out

 

 Out of house;

 

PrtY

 

 Party; 

 - one time charging of the HUW; 

2.

 

day of the week: 1 

 Mon., 2 

 Tue., 3 

 

Wed.,  4 

  Thu.,  5 

Fri.,  6 

  Sat.,  7 

 

Sun.; 

3.

 

clock  and  the  field  of  information 
displayed, 

eg 

menu 

descriptions, 

additional  operating  modes,  fuel  level, 
and external temperature; 

4.

 

symbol  when  displaying  the  external 
temperature value; 

5.

 

fuel level; 

6.

 

radio  connection  symbol  -  visible  only 
during an active radio connection with the 
radio  module.  When  it  is  always  visible, 
the  thermostat  is  not  paired  with  the 
radio  module,  and  when  it  is  flashing, 
there  is  permanent  loss  of  radio 
connection with this module; 

7.

 

indicator of battery discharge - when it is 
constantly on, it means that the batteries 
are  on  depletion,  and  when  it  flashes,  it 
means  that  the  batteries  are  already 
depleted and the thermostat has stopped 
communicating with the radio module; 

8.

 

unit symbols; 

9.

 

heating  symbol  -  the  symbol  is  visible 
when  the  heating  signal  is  being  sent  to 

Summary of Contents for eSTER x40

Page 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Page 2: ......

Page 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Page 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Page 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Page 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Page 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Page 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Page 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Page 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Page 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Page 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Page 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Page 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Page 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Page 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Page 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: