background image

 

of  5  seconds.  Editable  operating  modes  that 
are related to parameter settings in the user 
menu (point 11): 

 

Schedule

 

  the  preset  temperature 

changes 

between 

the 

"Night" 

temperature  (

P06

)  and  the  "Day" 

temperature  (

P05

),  according  to  the 

programmed time schedule (

P01

). 

 

Holiday

 

  the  preset  temperature  is  set 

single  time  to  the  "Holiday"  temperature 
(

P10

), which appears for editing: 

 

for the duration time (

P11

) of this mode, 

which  appears  for  editing  immediately 
after the temperature: 

 

After  this  time,  the  thermostat  goes  into 
the  mode  in  which  he  worked  before 
turning  on  the  "Holiday"  mode.  This 
mode  is  useful  when  traveling  on 
holidays. 

 

Comfortable 

-  thermostat  works  with  a 

constant  preset  temperature  "Day" 
(

P05

),  which  ensures  a  comfortable 

temperature in a heated room. 

 

Economical 

- the thermostat operates at 

a  constant  preset  temperature  "Night" 
(

P06

), which saves fuel. 

 

Antifreeze 

- the thermostat works with a 

constant  preset  temperature  "Antifreeze" 
(

P07

),  which  ensures  protection  against 

freezing  of  water  in  the  heating  circuit. 
This mode is useful when there is no one 
in the heated rooms. 

 

 - the mode enables a single charging 

of  the  HUW  container  for  the  set  time 
(

P14

), which appears for editing: 

 

During  the  active  single  charging  HUW 
container,  time  schedules  for  HUW  are 
switched off. 

 

Airing

  (text  information  on  3

rd

  item  of 

the 

main 

screen) 

 

the 

preset 

temperature  is  set  single  time  to  the 
"Night"  temperature  (

P06

),  for  the 

duration  time  (

P13

)  of  the  of  the  airing 

mode that appears for editing:  

 

After  this  time,  the  thermostat  switches 
to  the  mode  in  which  it  worked  before 
turning  on  the  "Airing" mode.  This  mode 
is  particularly  useful  when  ventilating 
rooms. 

 

Party

 (text information on 3

rd

 item of the 

main screen) 

 the preset temperature is 

set 

single 

time 

for 

the 

"Party" 

temperature  (

P08

),  which  appears  for 

editing: 

 

for the duration time (

P09

) of the of the 

"Party"  mode,  which  appears  for  editing 
immediately after the temperature: 

Summary of Contents for eSTER x40

Page 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Page 2: ......

Page 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Page 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Page 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Page 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Page 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Page 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Page 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Page 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Page 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Page 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Page 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Page 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Page 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Page 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Page 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: