background image

13 

 

 

Terminals D +, D-, GND, 12 VDC of the radio 
module  should  be  connected  to  the  RS485 
transmission socket of the main controller, in 
accordance with point. 15.5   

 

When  connecting  the  transmission 
and  power  supply  attention  should 
be  paid  to  the  proper  polarity  of 
connection of D +, D- and GND, 12 
V between the radio module and the 
main 

controller. 

Improper 

connection  may  lead  to  damage  to 
the  main  controller  or  errors  in  its 
operation. 

 

The maximum cable length depends 
on  the  cross-section  of  the  wires. 
For  a  0.5  mm

2

  wire,  it  should  not 

exceed  30  m.  The  cross-section 
should  not,  however,  be  less  than 
0.5 mm

2

 

 

15.2

 

Pairing the radio module with the 

thermostat 

 

The 

radio 

module 

connected 

electrically  to  the  main  controller 
requires pairing with a thermostat. 

Until  the  pairing  with  the  radio  module  on 

the  thermostat  screen  is  complete,  the 

 

and 

 symbols are permanently displayed. 

 
Pairing from the main controller menu: 

 

The pairing method is only available 
when the main controller program is 
fully  compatible  with  the  radio 
module. 

Enter the main regulator menu: 

MENU 

  General  settings 

  Radio 

module  settings 

→ 

Pairing  mode

  and  set 

the 

Pairing  mode

  to 

Yes

,  then  the  pairing 

mode will be activated for 4 minutes, during 
this  time  the  thermostat  with  the  radio 
module  should  be  paired.  To  do  this,  hold 

simultaneously 

  and 

  button  for  2 

seconds  in  the  thermostat  and  then  select 
the  program  (

P03

)  in  the  user  menu  of  the 

thermostat, where "

PAr

" is displayed on the 

screen.  After  accepting  with 

button,  the 

pairing  will  start  (the  word  "

PAr

"  begins  to 

flash). 

Screw holes 
 
Assembly screw 

Module

 

4x0.5 mm

2

 wire, 

max. length 30 m 
 
Assembly screw 

Summary of Contents for eSTER x40

Page 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Page 2: ......

Page 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Page 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Page 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Page 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Page 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Page 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Page 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Page 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Page 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Page 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Page 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Page 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Page 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Page 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Page 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: