MPS6100-M MAINTENANCE MANUAL
ORIGINAL INSTRUCTIONS
Page 2
1.0
GENERAL PROCEDURES
1.1
DE-ENERGIZING AND LOCKOUT PROCEDURE
CAUTION: Risk of electrical shock if the machine has not been properly de-energized and
locked out prior to performing maintenance procedures.
1)
First the machine must be powered off using the main power switch on the front of
the control box. Set the switch to the OFF position.
2)
Proceed to unplug the main power cord from the wall outlet or the back of the
control box. To lockout the machine the main power cord must be COMPLETELY
REMOVED and in the possession of the service technician at all times.
1.2
HEATING BAR COOLING TIME
The heating bars of the MPS6100 operate between 120°C and 180°C which can
cause serious burns if touched by the service technician. The table below shows average
cooling times from the maximum temperature of 200°C over a time lapse of ten minutes.
When the main power switch is set to the COOL position the machine will continue to
operate for ten minutes however the heater bars will not be energized allowing the machine
to cool down. When servicing the machine be aware of the possible dangers posed by the
temperature of the sealing bars.
CAUTION: Hot surfaces may be exposed. To prevent personal injury do not attempt to
touch the heating bars or surrounding areas while hot.