All electrical appliances produced for the Company are guaranteed for one year against faulty material or workmanship. This applies only if the appliance has 
been used for purposes in accordance with the instructions provided and has not been connected to an unsuitable electricity supply, or subject to misuse, neglect, 

damage or modified or repaired by any person not authorised by the Company. This guarantee is offered to you as an extra benefit and does not affect your legal 

rights. The correct electricity supply voltage is shown on the rating label attached to the appliance. Reasonable care has been taken to ensure that this guide is 
accurate at the time of printing. In the interest of progress the Company reserve the right to vary specifications from time to time without notice.

ELECTRIC TOWEL WARMER  

WITH REMOTE PROGRAMMER

Timelis

Summary of Contents for Timelis

Page 1: ... damage or modified or repaired by any person not authorised by the Company This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the rating label attached to the appliance Reasonable care has been taken to ensure that this guide is accurate at the time of printing In the interest of progress the Company reserv...

Page 2: ...thin minimum distances from obstacles Do not install the device In a draft likely to affect its control under centralised mechanical ventilation etc Under a fixed mains outlet Inside zones 0 and 1 in bathrooms The device has to be installed so that switches and other controls cannot be tou ched by a person in the bath or shower ex cept in the UK where IEE Regulations 701 512 2 and 701 512 3 apply ...

Page 3: ...such as bathrooms and kitchens install the connecting box at least 25cm from the ground If power cable is damaged or too short to avoid any danger it must be replaced by a qualified elec trician using special tools Heated towel rail wiring diagram Switch the power off and connect the wires as shown in the following diagram Live brown Neutral blue Panel heater cable LIVE NEUTRAL Electricity grid GB...

Page 4: ... back and resting flat on the floor Prick out the four drill holes though the packaging without drilling and then re move the packaging 2 Carefully mark the drilling points with a pencil draw a cross 4cm wide 3 Drill the four holes 4 Position the four hooks and screw them tight Puissance Cote A 300 W 819 mm 500 W 1209 mm 750 W 1599 mm ...

Page 5: ...ng the hanger 5 Screw the sup ports onto the tubes without blocking them Check their posi tion by putting them with the towel drying ra diator into the sheaths Once you found the right position lock the screws for each contact 6 Fit the towel drying radiator on the wall in the sheaths Screw down each of the locking blocks Put the caps on the end of the supports GB ...

Page 6: ...T Do not install the thermostat on an outside wall or in an unheated room e g garage etc fixed on the wall about 1 50 m off the ground placed on a piece of furniture 20 cm min Location Fixing Raise the cover with a screwdriver Using the screwdriver remove the batteries delivered with the device if fixed to the wall or remove the battery protection tab if fixed on stand Fixed to the wall Fix the th...

Page 7: ...re in the room thermometer and the temperature measured and displayed by the device this menu can be used to change the probe s measurement to compensate for this difference from 4 C to 4 C in 0 1 C steps Adjust the setting with or then press OK to confirm and move onto the next menu CF02 Temperature display in AUTO mode Adjust the setting with or then press OK to confirm and move onto the next me...

Page 8: ...On the transmitter in the CF06 menu press the key The transmitter sends a frame to the receiver The X2D symbol appears briefly Check that the light on the receiver has stopped blinbing The receiver is associated with the transmitter Press OK to move onto the next menu CF07 Radio test The transmitter sends a frame to the receiver every 3 seconds The X2D symbol appears briefly Check that the light o...

Page 9: ... whatever the type of controls you have cho sen manual or programmed Auto mode your heated towel rail will automatically switch between Eco mode and comfort mode de pending on the time slots programmed for each day of the week Comfort mode allows you to maintain the correct ambient temperature Boost mode used to start the heated towel rail in override mode for a certain period of time Eco mode use...

Page 10: ... C to 30 C 19 C by default Choose using or Turn the knob to exit the setting mode 3 Programming PROG When the device is first started up the Comfort from 6h to 23h program is applied to every day of the week To change the setting turn the knob to PROG The 1st time slot blinks Press Eco or comfort depending on how you want to program your device To apply the same program to the next day hold the OK...

Page 11: ... started up automatic mode measured temperature press the Programmed temperature 4 Frost Protection Mode Turn the knob to Frost Protection Use this mode to set the temperature from 5 to 15 C when you are away for a long time Set the temperature using or 5 Boost Mode Use this mode to start the heated towel rail in override mode for a certain period of time When in automatic mode AUTO press the BOOS...

Page 12: ...must be taken put the batteries the right way round in the device do not throw the used batteries away take them to a battery sorting centre do not recharge them you have about 45 seconds to change the batteries before the time is reset to zero if this happens you will need to set the time and date again 8 Returning to the original settings You can reset the device to return to the original factor...

Page 13: ...less the person responsible for their safety is supervising them or has given them instructions in advance on how to use the heated towel rail For avoid any danger for very young children you are advised to install this appliance so that the lo west heating bar is at least 600 mm from the floor For safety reasons it is strictly forbidden to re fill the appliance If this is needed contact the manu ...

Page 14: ... or that the temperature setting has not been changed There may be a hitch in the electrical supply If this is the problem a blocked thermostat for instance switch off the supply to the heated towel rail by removing the fuse or switching off the trip switch for about 10 mi nutes then switch it back on again If this happens frequently hove your power company check the supply The surface of the radi...

Page 15: ...15 ...

Page 16: ...tlantic Heat PO Box 103 National Avenue Kingston Upon Hull HU5 4JN Atlantic Heat is part of Ideal Boilers Limited Ideal Boilers Ltd pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice ...