MPS6100-M OPERATION MANUAL
ORIGINAL INSTRUCTIONS
Page 13
4)
The Down key – Move the set point value down.
5)
The Process Value display - the current temperature at which the machine is running.
6)
The Set Value display - the temperature that has been selected for operation.
The temperature controller is an auto-tune PID type, which should keep temperature
constant. There is a lockout setting on the temperature controller to prevent users from changing
the internal values of the temperature controller, if assistance is needed please get in touch with
Plexpack Technical Support.
Correct temperature setting can be determined by taking the time to test seal the samples of
material to be used. Too much heat will result in a heavy seal that weakens the material above and
below the seal while insufficient heat will result in a weak seal. The temperature of the MPS 6100
series should range between 130°C to 180°C.
1)
Press the MODE button and then the arrow keys to either raise or lower the set point
temperature to its desired value.
2)
Once you have selected the desired temperature, the controller retains the displayed
value.
3)
The value in the “Process Value” screen will now change to match your selected
temperature value. Once the “Process Value” matches the “Set Value,” the machine is
ready to seal your product.
FIGURE - 9
5
6
3
4
1
2