WWW.PITBOSS-GRILLS.COM
17
PIT BOSS® GRILLS
ENGLISH
"ErH" Error Code
The unit has overheated,
possibly due to grease fire
or excess fuel.
Press and hold the Power Button for three seconds to turn the unit off, and al-
low grill to cool. Follow Care and Maintenance instructions. After maintenance,
remove pellets, and confirm positioning of all component parts. Once cooled,
press the Power Button to turn the unit on, then select desired temperature. If
error code still displayed, contact Customer Care.
"ErP" Error Code
Grill probe wire not making
connection.
Remove the access panel and check for any damage to the Grill Probe wires.
Disconnect and reconnect the Grill Probe connectors to the Control Board.
Grill Probe is broken
Grill Probe need to be replaced. Contact Customer Care for a replacement.
"ErL" Error Code
Grill fails to perform
start-up cycle.
Check proper positioning of cooking components. Check hopper for sufficient
fuel or if there is an obstruction in the feed system. Remove pellets and follow
Care and Maintenance instructions. Check Grill Probe (Sensor) to confirm if
actual temperature is correct and accurate. Follow Care and Maintenance in-
structions if dirty. Check igniter positioning and that it is heating up properly.
In extreme cold, the grill may require a second start. Turn grill off, wait, then
turn on again. Check fan. Ensure it is working properly. Follow Care and Main-
tenance instructions if dirty.
Grill will not stay lit.
"NoP" Error Code
Bad connection at
connection port
Disconnect the meat probe from the connection port on the Control Board,
and reconnect. Ensure the meat probe adapter is firmly connected. Check
for signs of damage to the adapter end. If still failed, call Customer Care for
replacement part.
Meat probe is damaged
Check for signs of damage to the wires of the meat probe. If damaged, call
Customer Care for replacement part.
Faulty control board
Control Board needs to be replaced. Contact Customer Care for a replacement
part.
Auger Error Screen
Auger motor is jammed, not
making connection
Remove cooking components from the main barrel. Turn the unit on and
inspect the auger feed system. Visually confirm that the auger is dropping
pellets into the burn pot. If not operating properly, call Customer Care for
assistance or a replacement part.
Igniter Error Screen
Igniter is not working
properly, not making a
connection
Remove cooking components from the main barrel. Press and hold the Power
Button for three seconds to turn the unit on and inspect the igniter. Visually
confirm that the igniter is working by placing your hand above the burn pot
and feeling for heat. Visually confirm that the igniter is aligned with the hole
in the burn pot, and open to light the pellets. If not operating properly, call
Customer Care for assistance or a replacement part.
Igniter failure
Igniter needs to be replaced. Contact Customer Care for replacement part.
Fan Error Screen
Fan is not working properly,
not making a connection
Check fan. Ensure it is working properly and air intake is not blocked. Remove
access panel (see Electric Wire Diagram for diagram), and check for any dam-
age to the fan wires. Follow Care and Maintenance instructions if fan blades
are dirty.
Pellet Error Screen
Lack Of Fuel, Poor Fuel
Quality
Check hopper to check that fuel level is sufficient and replenish if low. Should
the quality of Hardwood pellets be poor, or the length of the pellets too long,
this may cause an obstruction in the feed system. Remove pellets and follow
Care and Maintenance instructions.
Summary of Contents for 10989