SECTION 3
El\llERGENCY PROCEDURES
PA-28-181
1
ARCHER
Ill
3.5 EMERGENCY PROCEDURES CHECK LIST (continued)
3.Sa Fire (continued)
Electrical Fire In Flight
EMERG BATT Switch ....................................................... VERIFY ARM
BA TT MASTR Switch ........................................................................ OFF
AL TR Switch ....................................................................................... OFF
Vents ................................................................................................ OPEN
HEAT/DEP (Defroster) ..................................................................... OFF
Fire ....................................................................................... EXTINGUISH
Emergency Descent (If needed) .......................... TO A SAFE ALTITUDE
Land as soon as possible.
REPORT: VB-2749
3-10
CONSISTENT WITH TERRAIN
ISSUED: December 22, 2017
•
•
•