SECTION 3
EJ\1E
R
GENCY PROCEDURES
PA-28-181, ARCHER
ill
3.Sf Pitot Heat Failure
Pitot Heat Failure
Indication: Master Caution, Double Chime,
P
ITOT HEA
T
FAIL
PITOT HEAT Switch .......................................................................... OFF
PITOT HEAT Circuit Breaker (Row 2, Col. 2) .............................. RESET
PITOT HEAT Switch ............................................................................ ON
If Pitot Heat still inoperative:
Exit and A void Instrument Meteorological Conditions.
3.Sg Starter Engaged
Starter Engaged
Indication: Master Warning, Triple Chime,
If
on the ground:
STARTENGD
THROITLE ................................................................................. REDUCE
ENG ST ART Circuit Breaker (Row I, Col. I 0) ............................... PULL
ENGINE ................................................................................ SHUTDOWN
If in
flight:
THROTTLE ................................................................................. REDUCE
ENG ST ART Circuit Breaker (Row I, Col. I 0) ............................... PULL
Land as soon as possible.
REPORT: VB-2749
3-38