![Pioneer Remix station RMX-1000 Service Manual Download Page 58](http://html.mh-extra.com/html/pioneer/remix-station-rmx-1000/remix-station-rmx-1000_service-manual_328610058.webp)
58
RMX-1000
1
2
3
4
A
B
C
D
E
F
1
2
3
4
(Reference) ALL RESET MODE
[Overview]
This mode is for resetting data of all setting items that are stored in nonvolatile memory. The setting items comprise
customized effect data, MIDI setting data, and adjustment data for the RELEASE FX lever.
This mode is designed to be used on the production line.
After ALL RESET is performed, be sure to perform calibration of the RELEASE FX lever.
[How to Enter ALL RESET Mode]
W
hile simultaneously holding the I
N
PUT, X-PAD, and KICK buttons pressed, turn the unit on.
[Special instructions]
• Test mode includes FACTORY RESET mode, but in FACTORY RESET mode, resetting of the adjustment data for the
RELEASE FX lever is not available.
[Details on ALL RESET Mode]
1
If the unit is started in ALL RESET mode, "rSt" is displayed on the 7-segment indicator.
2
To start resetting, press the HOLD button.
W
hile resetting is in progress, "rSt" on the 7-segment indicator and the HOLD button are flashing.
3
After resetting is properly completed, "End" is displayed on the 7-segment indicator and the HOLD button is steadily lit.
If resetting fails, "Err" will be displayed on the 7-segment indicator and the HOLD button will be steadily lit.
[Operating elements to be used for adjustment]
7-segment indicator
"rSt": Ready for reset start
"End": Resetting completed
"Err": Resetting failed because of an error
HOLD button
To be used to start resetting
Unlit: Ready for reset start
Flashing: Resetting in progress
Lit: Resetting completed
INPUT, X-PAD, and KICK buttons
To start ALL RESET mode, turn the unit O