Mode 6: "VOL" for confirmation of the values of the rotary variable controls and the
amplitude values
• This mode is for confirmation of the AD conversion value for each rotary
V
R on the operation panel with lighting of an
I
N
PUT/OUTPUT level indicator LED or the 7-segment indicator.
W
hen this mode is entered, “
V
oL” is displayed for 1 second on the 7-segment indicator.
• This mode consists of 10 modes for indicating the values of 10
V
Rs.
These 10 modes can be switched, using the
N
UDGE + or – button.
The current mode can be confirmed with the OUTPUT level indicator.
• The maximum amplitude value among AD conversion values for a
V
R being tested can be confirmed in each mode.
The maximum amplitude values are indicated with the X-PAD FX SOURCE selection button LEDs.
For measuring, first set the
V
R to be tested to a desired position then press the HOLD button to start measuring.
W
hen the HOLD button is pressed, all the LEDs other than the ROLL, KICK, S
N
ARE, CLAP, HIHAT, and O
V
ERDUB
buttons are lit.
To reset, press the HOLD button again. During measurement, the maximum amplitude value will be continuously
displayed.
The HOLD button is lit during measurement and turns to dim lighting after being reset.
Details on the amplitude value display are shown in the table and figure below.
• AD conversion values after a fluctuation removal process can be confirmed.
An AD conversion value after a fluctuation removal process will be displayed if the AUTO button is pressed while an AD
conversion value is being displayed.
The AUTO button is lit while the value after a fluctuation removal process is being displayed. To return to the value before
a fluctuation removal process, press the AUTO button again.
Maximum amplitude value
LED to be lit
1
ROLL
2
ROLL, KICK
3
ROLL, KICK, S
N
ARE
4
ROLL, KICK, S
N
ARE, CLAP
5
ROLL, KICK, S
N
ARE, CLAP, HIHAT
6
ROLL, KICK, S
N
ARE, CLAP, HIHAT, O
V
ERDUB
Higher than 6
ROLL, KICK, S
N
ARE, CLAP, HIHAT, O
V
ERDUB
Example:
In a case of a maximum amplitude value of 3
An amplitude value in the range of ±1 to ±5 with regard to the
V
R value at the beginning of measurement is displayed.
The maximum amplitude values of +6 or higher or –6 or lower are indicated with all 6 buttons lit.
ROLL
KICK
S
N
ARE
CLAP
HIHAT
O
V
ERDUB
[Use of this mode during repair]
• For failure judgment of the rotary
V
Rs
As a guide, amplitude values higher than +4 or lower than -4 may be judged as failure. The
V
Rs can be set to
any position during measurement. Possible symptoms are shown below.
• The volume changes arbitrarily.
• The MIDI signal is output even if the corresponding
V
R is not operated.
• For operation check of a rotary
V
R after replacement