ZX Series USER MANUAL
27
Fig. 3-18 Air Assist Installation
Push the ¼” tubing into the Air Flow valve. Pull on the tubing to make sure that it is locked
into place.
The outer ring of the valve needs to be pushed in before the tubing can be released.
Open the Air Flow valve. The valve has a dial that allows and restricts airflow. To avoid
damage to the air compressor, never fully close the Air Flow valve. Adjust the valve to find the
setting that is best for each application. (See fig. 3-19)
NOTE: It is important that the ¼” tubing has clean, straight cuts on each end. Any jagged or
slanted cuts will not produce a good seal between the tubing and the valve. Use a sharp knife
on a flat surface to ensure a proper cut.
Fig. 3-19 Air Assist Installation
Test the Air Assist System. Turn on the air compressor and make sure that the Air Flow valve
is open. The air nozzle located near the Auto Focus Gauge should emit a steady flow of air. If
the Air Assist System is not functioning properly, double-check the installation steps. If the
system is still not working properly, consult your ZX Series dealer.