UPS PIco HV3.0A Firmware Code 040 Print Date 18.08.2017
Designed and Manufactured by PiModules and ModMyPi
www.pimodules.com www.modmypi.com
UPS PIco HV3.0 HAT LEDs
The
UPS Pico HV3.0 HAT
is equipped with 6 LEDs (that offers information about the
UPS Pico HV3.0 HAT
system status. Three of them are dedicated for user applications
and can be handled by the
PICo
(I
2
C) interface. One of them is
Orange
, the second one
is
Green
, and the third is
Blue.
A detailed description of the system LEDs and their
usage is provided on below table.
System LEDs Indications
UPS LED
OFF
System is not running or is in Low
Power Mode (only HW RTC is
running)
Lighting continuously
System (PIco + RPi) is booting or
shutting down
Blinking every 400 ms for 400 ms
System (PIco + RPi) is running on
cable powering (after booting time)
Blinking every 1200 ms for 400 ms
System (PIco + RPi) is running on
battery powering
BAT LED
OFF
Battery level is
above
warning
thresholds:
-
For LiPO Battery
3.6V
-
For LiFePO4
2.95V
Lighting continuously
Battery level is
below
warning
thresholds:
-
For LiPO Battery
3.6V
-
For LiFePO4
2.95V
CHG LED
OFF
Battery is not Charged
Lighting continuously
Battery is Charged (and current is
flowing to the battery)
If battery is Full, even if Charger is ON,
current is not flowing to the battery,
so CHG LED is OFF
HOT LED
FAN LED
OFF
FAN is not running
Lighting continuously
FAN is running
EXT LED
OFF
External
Cable
powering
is
disconnected (7-28VDC)
Lighting continuously
External Cable powering is connected
(7-28VDC)
Table
9