UPS PIco HV3.0A Firmware Code 040 Print Date 18.08.2017
Designed and Manufactured by PiModules and ModMyPi
www.pimodules.com www.modmypi.com
Factory Defaults Setting
UPS PIco HV3.0 HAT
is offering feature that allows to revert setting to Factory Default. To do
this user has 2 was: based on command line (automatic recall), and manually. Both are
described here below.
Command Line Factory (automatic) recall
Then write the following command on the Raspberry Pi command line
Manually Factory Defaults recall
You can do this instead of using the automatic initiation outlined above. However, user need
to have physically access to the device, as needs to push buttons.
The following procedure needs to be followed:
•
Press and hold the
UR
button
•
Continue to hold the
UR
button, and press and hold the
C
button.
•
Release the
UR
button, but keep holding the
C
button
•
Release after 2 second the
C
button
The User LEDs (all of them) will blinking for a short time, then
UPS PIco HV3.0 HAT
will be
restarted. It is mandatory, to have system cable powered during factory recall process (totally
about 5 seconds)
UPS PIco HV3.0 HAT settings on Factory Defaults recall
The following setting are setting when Factory Defaults recall.
1.
UPS PIco HV3.0 HAT
EEPROM ERASE
2.
Still Alive Timer
sets to 0xff (OFF)
3.
Hardware RTC
sets to default values:
•
Seconds
•
minutes
4.
FAN Speed
sets to 50%
5.
FAN
sets to Automatic mode
6.
FAN TO92 sensor
temperature sets to 35 Celsius
7.
Auxiliary 5V@750mA
and
3.3V@150mA
sets to OFF
8.
Running on Battery
sets to 60 seconds