UPS PIco HV3.0A Firmware Code 040 Print Date 18.08.2017
Designed and Manufactured by PiModules and ModMyPi
www.pimodules.com www.modmypi.com
Action Duration
= 0001;
means it will run for 1 minute
Action Repetition Time
= 02;
means it will be repeated after 2 minutes from
starting time of the earlier one
Action Multiplier
= 60;
means it will happen 60 times within the same
Sequence
Sequence Repetition Time
= 24;
means this (above described) sequence will be
repeated every day (every 24 hours).
0x6e -> ETR SAS Actions Stamp
Action RPi_PON
= 0x01;
means that Action of this Scheduler will be
Raspberry
Pi® ON
and
(after Action Duration Time)
OFF
0x6f -> ETR SAS Events Stamp
Not involved. Keep all values 0x00.