Operation
Operating Manual PSEN sg2c
1003267EN02
41
9
Operation
Check the function of the safety switch before commissioning.
Teaching in the actuator
}
PSEN sg2cxxx (versions with basic coding)
Any corresponding Pilz actuator (see Technical details) is detected as soon as it is
brought into the response range.
}
PSEN sg2cxxx 2.2 (versions with full coding)
The first corresponding actuator to be detected by the safety switch (see Technical de
tails) is taught in automatically as soon as it is brought into the response range.
NOTICE
Please note: No other actuator may be taught in once an actuator has been
taught.
Status indicators
}
"Device" LED illuminates green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Bolt tongue is engaged
}
"Input" LED lights up yellow: Input circuits are closed or a HIGH signal is present
}
"Lock" LED illuminates blue: The guard locking element is engaged in the bolt tongue,
guard locking is active. Signals X16 and X17 (or X26 and X27) are present.
}
"Lock" LED illuminates green: The guard locking element is engaged in the bolt tongue,
guard locking is active. Signals X16 and X17 (or X26 and X27) are not present.
}
LED "Lock" flashes green and blue: Pushbutton 2 for access requirement was con
firmed and the machine stop was requested.
Pushbutton status displays (pushbutton see device versions):
}
Pushbutton LED [1] lights up: The guard locking element is engaged in the bolt tongue,
guard locking is active. Signals X16 and X17 (or X26 and X27) are not present.
The pushbuttons 3 and 4 can be used depending on the requirement and device version.
}
Pushbutton LED [3] can be used depending on the application. It is operated via the in
put (see Terminal assignment).
}
Pushbutton LED [4] can be used depending on the application. It is operated via the in
put (see Terminal assignment).