Function description
Operating Manual PSEN sg2c
1003267EN02
13
INFORMATION
When the escape or auxiliary release is operated, there is a low signal at
the safety outputs X13 and X14. An error code is issued. The PSENsgate
is not ready for operation again until the escape release or auxiliary release
has been reset to its unoperated state and the error has been reset.
Please note that the cover of the escape release has to be checked and in
stalled again after operation.
4.4
Pushbutton
Pushbutton 1
Pushbutton 2
Pushbutton 1
Pushbutton 2
Pushbutton 3
Pushbutton 4
PSEN sg2c-3...
PSEN sg2c-5...
}
Pushbutton 1: Pushbutton for activating the guard locking of the safety gate
Pressing the pushbutton for activating the interlock engages the guard locking element
into the bolt tongue.
}
Pushbutton 2: Pushbutton for access request and release of the safety gate
–
Pressing the pushbutton for access request disengages the guard locking element
from the bolt tongue when a high signal is present at X16 and X17 or at X26 and
X27 (solenoid operation).
–
Pressing the pushbutton for access request switches output X15 (access request)
when a low signal is present at X16 and X17 or at X26 and X27 (solenoid opera
tion).