Wiring
Operating Manual PSEN sg2c
1003267EN02
23
5.6
ESTOP pushbutton connection
CAUTION!
With versions with integral ESTOP pushbutton, the ESTOP pushbutton
(terminals X110 to X113) must be integrated into the plant/machine's E
STOP concept in accordance with EN/IEC 60204.
5.7
Enabling switch connection
Details of the pin assignment of the female 5pin M12 connector for the enabling switch can
be found in the block diagram and the terminal configuration.
We recommend you use the PIT en1.0p5ms (order no. 401 110) as the enabling switch.
5.8
EMC requirements
Please note:
}
The power supply must meet the regulations for extra low voltages with protective sep
aration (SELV, PELV).
}
The inputs and outputs of the safety switch must have a protective separation to
voltages over 60 V AC.
}
The supply voltage has to be at the safety switch terminals within the indicated toler
ances (see Technical details).
}
the supply voltage of the safety switch must be secured with a fuse of type quick
between 2 A and 10 A.
}
The electrical installation must be performed in accordance with IEC/EN 60204.
}
The assured release distance (S
aO
) can be influenced by external influences (e.g.: tem
perature, dirt, EMC) (see Technical details).