Installation
Operating Manual PSEN sg2c
1003267EN02
31
}
Unscrew the pressure screw from the housing and remove the rubber seal.
}
Thread the cable through the correctly oriented pressure screw and the rubber seal, re
move the blind insert if necessary.
}
Remove the countersunk screws at the housing cover for the connection terminals and
slowly remove the housing cover. In doing so, the spring mechanism moves the cover
of the escape release upwards.
}
Unscrew the plate of the strain relief.
}
Connect and insert connection terminals.
}
Position cable and screw on the strain relief plate (torque setting 0.9 Nm (8 inlbs)).
}
Fix housing cover with screws (torque setting 1.7 +/ 0.1 Nm (15 inlbs)).
}
Move the rubber seal along the cables and position it in the housing.
}
Screw pressure screw on the thread.