English
41
USE
PELLET HOPPER HOUSING TEMPERATURE
Sensor
Description
Display
Thermostat with
automatic reset
Located on the pellet hopper, its function is to
prevent excessive temperature ranges.
WHEN ACTIVATED
If the pellet hopper temperature reaches critical
levels, the thermostat cuts off the power supply to
the fuel-loading auger, thereby stopping the
supply of pellets to the grate and starting the
stove shutdown process.
• The readout “ALC” appears in the STOVE
STATUS mode.
• After approx. 60 seconds the alarm sounds (if
activated).
WHAT TO DO
- Shut down the stove by holding the ON/OFF key
down for several seconds
• The alarm will stop.
• Wait until combustion of any pellets remaining in
the grate has finished.
• After having cleaned the grate, restart the stove
by pressing the ON/OFF key. (The readout
SAFETY THERMAL must no longer appear on the
display. If this is not the case repeat the process
described above.)
DT2010995-00
S A F E T Y
T H E R M A L
!
1
!
!