26
USE
Action
Function
Display
Press the
TEMPERATURE
key
and select
To adjust the temperature setting, press the TEMPERATURE
key and select the desired temperature by using the
SELECT key (range 7°C to 30°C). When the desired
temperature has been reached the readout
OK
appears in
the initial display and the stove operates at minimum
power even if the display shows the originally set power
level. The temperature can be read by the remote control,
by the stove itself or by an external thermostat. To choose
whether the remote or the stove will read the temperature
see the section entitled PROGRAMMING, paragraph
MULTICOMFORT. If using an external thermostat the
readout
"
ton
" appears in the initial display and the
readings from the stove and the remote control are cut out.
During normal operation the automatic grate cleaning
function activates periodically, the frequency varying
according to the settings pre-programmed by Gruppo
Piazzetta personnel. This operation removes ash deposits
and other buildups, which would otherwise prevent correct
stove operation. The readout "
PUL
" appears in
STOVE
STATUS
along with the flue gas temperature. See the
Programming section.
DT2040062-04
S E T
T E M P
R O O M
2 6
!
!
1
.
c
C L E A N I N G
B R A Z I E R
1 2 : 0 0
2 6
!
!
1
.
c
MENU
SET
ESC
OPT
MENU
SET
ESC
OPT
EXTERNAL THERMOSTAT
Action
Function
Display
Stove operation can be regulated by any kind of external
room thermostat connected to the electronic board.
To connect the thermostat, see paragrap
“Installing the
external room thermostat”.
Operation of the external thermostat depends on the stove
temperature setting.
- If the set stove temperature is less than the room
temperature, the external thermostat prevails. (It is
advisable to set a minimum value of 7°C for the stove).
- If the set stove temperature is more than the room
temperature, the internal stove thermostat prevails. The
external thermostat is disabled.
The room sensor must be connected. If the
room sensor is not connected the appliance
does not modulate the power and operates to
user settings.
DT2040059-06
SHUTDOWN
Action
Function
Display
Hold the ON/OFF
key
down
for
several seconds
Fuel loading stops, while the cooling fan and the extractor
fan continue to operate for approx. another 10 minutes
until the stove has cooled.
The readout "PUL" appears in STOVE STATUS along with
the flue gas temperature. See the section on programming.
Never unplug the stove from the power supply at this stage as this could cause internal problems and compromise
subsequent ignition operations.
DT2040060-04
MENU
SET
ESC
OPT
C L E A N I N G
B R A Z I E R
1 2 : 0 0
2 2
!
!
1
.
c