5 Installation
E-625 Piezo Servo Controller
PZ166E
Version: 2.0.0
21
For the E-625.CR to be interlinked and all other piezo server controllers for capacitive
sensors to be added to the network (e.g. E-665.CR), the master/slave setting has been
made for the sensor synchronization, see "Synchronizing the Sensors" (p. 41) or the
E-665 user manual.
Tools and Accessories
One E-625.CN network cable for each device to be connected to the network, available
as an optional accessory (p. 12)
Alternatively: Suitable connection cables with the same pin assignment as the E-625.CN
(p. 73)
Networking the Controllers
Figure 4: Interlinking via E-625.CN network cable
Connect the
Network
sockets on the rear panels of the housings using the E-625.CN
cables (see figure) or other suitable connection cables.
Networking can be done in a series or as a star. The E-625.CN cables have D-sub special
connectors with which several E-625.CN cables can be plugged into one E-625. The
communication master can be selected as desired.
Details on network operation (e.g., for setting the channel names) are in the user manual for
the E-816 computer interface submodule.