FL SWITCH 2000
84
PHOENIX CONTACT
107065_en_01
Noise immunity according to EN 61000-4-6 (IEC 1000-4-6) (conducted)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-4 (IEC 1000-4-4) (burst)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-5 (IEC 1000-4-5) (surge)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion A
Test intensity 1, criterion A
Conformance with EMC Directives
Additional certifications
RoHS
@EEE 2002/95/EC - WEEE 2002/96/EC
IECEx:
IEC 60079-0:2011, 6th Edition
IEC 60079-15:2010, 4th Edition
ATEX:
EN 60079-0:2012+A11:2013
EN 60079-15:2010
Field of application:
II 3 G Ex nA IIC T4 Gc
IECEx ULD 16.0018X
Differences between this version and previous versions of the user manual
Rev. 00: initial version
Rev. 01: devices added