11.3
Technical data for devices in the 2200 version
Cable impedance
100 ohms
Transmission speed
10/100/1000 Mbps
Maximum network segment expansion
100 m
Ethernet interfaces (Fortsetzung)
Mechanical tests
Shock testing according to IEC 60068-2-27
Operation: 30g,
half-sine shock pulse
Vibration resistance according to IEC 60068-2-6
Operation/storage/transport: 2g, 10 Hz - 150 Hz
Free fall according to IEC 60068-2-32
1 m
Conformance with EMC Directives
Developed according to IEC 61000-6-2
Noise emission according to EN 55022: 1998
+ A1: 2000 + A2: 2003 (interference voltage)
Class A (industrial applications)
Noise emission according to EN 55011: 1998
+ A1: 1999 + A2: 2002 (electromagnetic interference)
Class A (industrial applications)
Noise immunity according to EN 61000-4-2 (IEC 1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge:
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion B
Test intensity 3, criterion A
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-3 (IEC 1000-4-3)
(electromagnetic fields)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-6 (IEC 1000-4-6) (conducted)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-4 (IEC 1000-4-4) (burst)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-5 (IEC 1000-4-5) (surge)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion A
Test intensity 1, criterion A
Additional certifications
RoHS
@EEE 2002/95/EC - WEEE 2002/96/EC
General data
Function
Ethernet/Fast Ethernet Switch; conforms to standard IEEE 802.3/802.3u
Switch principle
Store and forward
Address table
8192 MAC addresses
SNMP
Version 2c, Version 3
Transmission capacity per port
64-byte packet size, half duplex
At 10 Mbps:
14880 pps (packets per second)
At 100 Mbps:
148800 pps
Supported MIBs
MIB II and private SNMP objects from Phoenix Contact
Housing dimensions (width x height x depth) in mm
45 x 130 x 115 (depth from top edge of DIN rail)
Summary of Contents for FL SWITCH 2005
Page 1: ...User manual FL SWITCH 2000 Order No...
Page 62: ...FL SWITCH 2000 62 PHOENIX CONTACT 107065_en_01...
Page 68: ...FL SWITCH 2000 68 PHOENIX CONTACT 107065_en_01...
Page 87: ...Technical data and ordering data 107065_en_01 PHOENIX CONTACT 87 49 5281 9 462888...
Page 88: ...FL SWITCH 2000 88 PHOENIX CONTACT 107065_en_01...
Page 92: ...FL SWITCH 2000 92 PHOENIX CONTACT 107065_en_01...
Page 94: ...FL SWITCH 2000 94 PHOENIX CONTACT 107065_en_01...
Page 98: ...FL SWITCH 2000 98 PHOENIX CONTACT 107065_en_01...