PSI-MODEMSHDSL/SERIAL
5-8
PHOENIX CONTACT
104275_en_c00
186
Device supplied via USB
port only
VCC LED blink-
ing (1 Hz)
This message is generated when
the device is supplied via the USB
port only. No data traffic may take
place, since the DSL chip is reset
to save energy.
–
187
DIAG LED set
DIAG LED on
An error event caused the DIAG
LED to be set.
–
188
DIAG LED reset
DIAG LED off
The DIAG LED was reset (auto-
matically or manually).
–
189
reserved
190
No frequent link losses
anymore
–
After link losses occurred fre-
quently, the link is stable now (for
10 minutes at least), or the link has
been interrupted for 10 minutes at
least without having found a link
partner.
–
191
reserved
192
reserved
193
reserved
194
reserved
195
reserved
196
reserved
197
reserved
198
A DTE device is con-
nected to the RS-232 in-
terface.
–
There is a device connected via a
1:1 cable which acts as DTE (cor-
responds to eg a PC).
There is a device connected via a
crossover cable which acts as
DCE (corresponding to eg a con-
ventional modem).
–
199
A DCE device is con-
nected to the RS-232 in-
terface.
–
–
There is a device connected
via a 1:1 cable which acts as
DCE (corresponding to eg a
conventional modem).
–
There is a device connected
via a crossover cable which
acts as DTE (corresponds to
eg a PC).
–
200
No more too long frames
are received.
–
Previously, frames were received
which were too long (longer than
500 characters). Since one minute
no more too long frames were re-
ceived.
–
Table 5-1
Diagnostic IDs
No.
Meaning
LED
Possible cause(s)
Remedy