Diagnostic Software
EN 44
LX7500R
5.
Display and Control Board (DCB)
Example
DS:> 925
The entirely disc will be erased.
Are you sure you want this?[y/n]
092500:
Test OK @
Nucleus Name
DS_BE_RegionCodeSet
Nucleus Number
928
Description
Set the region code in the AV3.
User Input
Region code
Example
DS:> 928 1
092800:
Test OK @
DS:> 928
This nucleus is not supported by the engine
092800:
Test OK @
Nucleus Name
DS_BE_RegionCodeGet
Nucleus Number
929
Description
Read the region code from the AV3.
User Input
None
Example
DS:> 929
092900: DVD region 1
Test OK @
DS:> 929This nucleus is not supported by the engine
092900:
Test OK @
Nucleus Name
DS_BE_RegionCounterReset
Nucleus Number
930
Description
Reset the region counter in the AV3.
User Input
None
Example
DS:> 930
093000:
Test OK @
DS:> 930 This nucleus is not supported by the engine
093000:
Test OK @
Nucleus Name
DS_BE_AdjustLaserControl
Nucleus Number
931
Description
Adjust the DVD-M (with the OPU) with PCBA. (So adjusts the two PCBS to each other)
User Input
None
Execution Time
30 seconds
Example
DS:> 931
093100:
Test OK @
Nucleus Name
DS_DCB_CommunicationEcho
Nucleus Number
1000
Description
Check the communication between the digital board and the DCB by issuing an echo
command
User Input
None
Example
DS:> 1000
100000:
Test OK @
Nucleus Name
DS_DCB_VersionGet
Nucleus Number
1001
Description
Get the version of the DCB