OPERATION
TIMER
STANDBY
FILTER
Installation Instructions
Wireless Receiver for ALL
Model No.
CZ-RWSC3
(1)
Light receiving section
Receives signals.
(2)
Emergency operation button
Starts/Stops emergency operation.
(3)
Indication lamp
Indicates operation status.
Supplied accessories
Wood screw
M4 × 15.5
(2)
Clamper
(1)
Part Names
Printed in China
T1114-1
F616441
Safety Precautions
Read before installation
Read the Installation Instructions carefully to install the unit
correctly and safely.
Be sure to read the Safety Precautions in particular before
installation.
After the installation is complete, perform test operation to confi rm
that no abnormality is present.
We assume no responsibility for accidents or damages resulting
from methods other than those described in the installation
instructions or methods without using specifi ed parts.
Malfunctions that occurred due to the unauthorised installation
methods are not covered by the product warranty.
Read the installation instructions supplied with indoor units as well.
WARNING
This symbol refers to a hazard or
unsafe practice which can result in
severe personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe
practice which can result in personal injury
or product or property damage.
WARNING
• Turn off the circuit breaker of
the units before installation.
• Ask your dealer or
professionals for installation
and electric work.
• This receiver shall be installed
in accordance with National
Wiring Regulations.
• Securely connect and fi x the
specifi ed cables for wiring.
• Do not allow the connection
to be exposed to the external
force of the cables.
• Choose an installation location
that suffi ciently supports the
weight of the receiver.
CAUTION
Do not use at the following locations.
• Location where condensation occurs
• Location where fl ammable gases, etc. may leak
• Location where corrosive gases, etc. may leak
• Location with lots of water or oil droplets
(including machine oil)
• Location where voltage fl uctuation frequently
occurs
• Location where there is a machine producing
electromagnetic radiation
• Location where droplets of organic solvents
spread
• Location where acidic or alkaline solutions or
special sprays are frequently used
Do not operate with wet hands.
Do not wash with water.
g
n
i
t
t
e
S
g
n
i
t
n
u
o
M
Installation Precautions
Specifi cations
Dimensions
Wiring for the receiver
Wiring diagram
Type of wiring
Use cables of 0.5 to 1.25 mm
2
.
Total wire length:
400 m or less
(The wire length between indoor
units should be 200 m or less.)
Number of connectable units
Remote controller and receiver: Max. 2, Indoor unit: Max. 8
Attention
R1 R2
R1 R2
R1 R2
1 2
1 2
1 2
Wired RC
Receiver
t
i
n
u
r
o
o
d
n
I
t
i
n
u
r
o
o
d
n
I
t
i
n
u
r
o
o
d
n
I
RC wiring
Receiver
*Wiring as shown below is prohibited.
1
2
R1
R2
Indoor unit
Terminals for RC wiring
Receiver
RC wiring (fi eld supply)
• No polarity
Model No.
CZ-RWSC3
Dimensions
(H) 120 mm × (W) 70 mm × (D) 20 mm
Weight
75
g
Temperature/Humidity range
0 °C to 40 °C / 20 % to 80 % (No condensation)
*Indoor use only.
Power Source
DC16 V (supplied from indoor unit)
Installation when setting Main/Sub for the remote controller and the receiver
After installation, according to the "Main/Sub setting" in the "Setting" section, set one to [Main] and the other to [Sub].
Setting the wired remote controller to [Main] is recommended.
The remote controller and the receiver can be connected to any indoor unit for operation.
Note
Main/Sub setting
Address setting
Remove the top case of the receiver for setting.
Main/Sub setting
1 2 3 4
Switch
ON
OFF
Use this to set Main/Sub for the remote controller and the receiver.
Set one to [Main] and the other to [Sub].
Factory default: [Main]
It is recommended to set the wired remote controller to [Main].
B
U
S
N
I
A
M
b
u
S
/
n
i
a
M
Main/Sub switch position
1 2 3 4
1 2 3 4
Address setting
When more than 1 receiver is installed in the same room, setting addresses prevents interference.
For how to change addresses of wireless remote controllers, see operating instructions of wireless remote controllers.
Wireless
remote controller
address display
Address
Address
Address
Address
Address
Address
Address
ALL
1
2
3
4
5
6
Address
switch position
Receiving is
possible at all
address positions.
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Test operation
Preparation
: Turn on the circuit breaker of units and then turn the power on. After the power is turned on, remote controller operation is ignored
for approx. 1 minute because setting is being made. This is not malfunction. (Contents received while setting are disabled.)
1. To start test operation, press and hold the emergency operation button for 10 seconds.
2. The indication lamps (OPERATION, TIMER, STANDBY) blink during test operation.
3. To fi nish test operation, press and hold the emergency operation button for 10 seconds.
Attention
Do not use this mode for purposes other than the test operation.
(To prevent overload of the units)
Read the installation instructions supplied with the units.
Any of the Heat, Cool and Fan operations can only be performed.
Temperature cannot be changed.
The test operation mode is automatically turned off in 60 minutes.
(To prevent continuous test operation)
Outdoor units do not operate for approx. 3 minutes after the power is
turned on or operation is stopped.
Self-diagnostics table and detected contents
The "Alarm Display" as shown in the table below expresses the alarm contents displayed when the wired remote controller is connected. For
how to handle the alarms, see installation instructions of indoor units or technical guide.
r
e
v
i
e
c
e
r
e
h
t
n
o
p
m
a
l
n
o
i
t
a
c
i
d
n
I
s
t
n
e
t
n
o
c
d
e
t
c
e
t
e
D
Alarm Display
OPERATION
TIMER
STANDBY
Blinking
Communication error in the remote control circuit
E01–E03, E08–E14, E17, E18
Communication error either in the in/outdoor operation line or
the sub-bus of the outdoor unit
E04–E07, E15, E16, E19–E31
Operation of indoor protection device
P01, P09–P14
Alternately
1
3
P
–
5
1
P
,
8
0
P
–
2
0
P
e
c
i
v
e
d
n
o
i
t
c
e
t
o
r
p
r
o
o
d
t
u
o
f
o
n
o
i
t
a
r
e
p
O
Alternately
1
1
F
–
0
1
F
,
3
0
F
–
1
0
F
r
o
t
s
i
m
r
e
h
t
r
o
o
d
n
i
e
h
t
n
i
r
o
r
r
E
Alternately
8
2
F
–
2
1
F
,
9
0
F
–
4
0
F
r
o
t
s
i
m
r
e
h
t
r
o
o
d
t
u
o
e
h
t
n
i
r
o
r
r
E
Alternately
9
2
F
M
O
R
P
E
E
r
o
o
d
n
i
e
h
t
n
i
r
o
r
r
E
Simultaneously
1
3
F
,
0
3
F
M
O
R
P
E
E
r
o
o
d
t
u
o
e
h
t
n
i
r
o
r
r
E
Simultaneously
1
3
H
–
1
0
H
r
o
s
s
e
r
p
m
o
c
e
h
t
o
t
d
e
t
a
l
e
r
r
o
r
r
E
9
0
L
–
5
0
L
,
3
0
L
–
1
0
L
s
g
n
i
t
t
e
s
r
o
o
d
n
i
n
i
r
o
r
r
E
Simultaneously
1
3
L
–
0
1
L
,
4
0
L
s
g
n
i
t
t
e
s
r
o
o
d
t
u
o
n
i
r
o
r
r
E
Simultaneously
Inconsistency in Air/Heat (Including an auto-temp setting
for a model without auto-temp settings)
Alternately
Oil Alarm (Same as operation of outdoor protection device)
Alternately
Test operation
Simultaneously
: OFF
: ON (Illuminated)
: Blinking (0.5 seconds interval)
NOTICE
The English text is the original instructions. Other languages are translation of the
original instructions.
1 2
1 2
R1 R2
R1 R2
R1 R2
R1 R2
RC wiring (fi eld supply)
• No polarity
Indoor unit
Indoor unit
Indoor unit
Indoor unit
1 2
1 2
R1 R2
Terminals for
RC wiring
)
b
u
S
(
r
e
v
i
e
c
e
R
)
b
u
S
(
r
e
v
i
e
c
e
R
Wired RC (Main)
Wired RC (Main)
Indoor unit
Using 1 indoor unit
Using more than 1 indoor unit
RC wiring
(fi eld supply)
• No polarity
Installation
example
70
4.4
4.4
2.
8
1
3.
8
1
83.5
20
120
34.4
8
5.4
Unit: mm
14
9.4
12
1
Remove the bottom case.
Attention
Mounting the bottom case
Tighten the screws securely until the screw
heads touch the bottom case.
(Otherwise, loose screw heads may hit the
PCB and cause malfunction when mounting
the top case.)
Do not over-tighten the screws.
(The bottom case may be deformed, resulting
in fall of the unit.)
Connecting the remote control wiring
Arrange the wires as shown in the illustration for
➋
in step
2
,
avoiding unnecessary wires being stored in the case. (Caught
wires may destroy the PCB.)
Avoid wires touching parts on the PCB.
(Caught wires may destroy the PCB.)
Flat-blade
screwdriver
Bottom
case
Insert the driver
and slightly turn.
2
Mount to the wall.
e
p
y
t
d
e
d
d
e
b
m
E
e
p
y
t
d
e
s
o
p
x
E
Preparation
: Make 2 holes for screws using a driver.
Preparation
: Make 2 holes for screws using a driver.
1
3
2
Cut here with a
nipper and remove
the burr with
a fi le.
Mount the top case.
Align the claws of
the top case and
then align the claws
of the bottom case.
Mount the bottom case
to the wall.
Connect the remote control wiring.
Arrange the wires along the groove of the case.
Wood screw (supplied)
Claw
Hole for screw
Wall to fi x the
receiver
Claw (2 places)
Top case
(Back side)
Remove the coating. Approx. 6 mm
Remove the sheath. Approx. 150 mm
Make sure the wiring connection
is in the correct direction.
Clamper
(supplied)
Pass through
the hole.
Bottom case (Back side)
1
3
2
Avoid the wire
being caught.
Mount the top case.
Align the claws of
the top case and
then align the claws
of the bottom case.
Mount the bottom case to
the wall.
Pass the wire through the hole
in the centre of the bottom case.
Connect the remote control wiring.
Wood screw (supplied)
Claw (2 places)
Claw
Hole for screw
Terminal board
Bottom case (Back side)
Remove the coating.
Approx. 6 mm
Make sure the wiring connection
is in the correct direction.
Top case
(Back side)
ENGLISH
欧州CZ-RWSC3据付(電気)工事説明書̲En.indd 1
欧州CZ-RWSC3据付(電気)工事説明書̲En.indd 1
2014/02/07 10:49:51
2014/02/07 10:49:51
Be careful not to connect cables to other terminals of indoor units (e.g. power source wiring
terminal). Malfunction may occur.
Do not bundle together with the power source wiring or store in the same metal tube. Operation
error may occur.
If noise is induced to the unit power supply, attach a noise filter.
For the RC wiring of field supply, please use insulated wires with sheath.
The insulation thickness should be at least 1 mm.
Regulations on wire diameters differ from locality to locality. For field wiring
rules, please refer to your LOCAL ELECTRICAL CODES before beginning.
You must ensure that installation complies with all relevant rules and regulations.