background image

OPERATION

TIMER

STANDBY

FILTER

Installation Instructions
Wireless Receiver for ALL

Model No.

 CZ-RWSC3

(1) 

 Light receiving section

Receives signals.

(2)  

Emergency operation button

Starts/Stops emergency operation.

(3)  

Indication lamp

Indicates operation status.

Supplied accessories

Wood screw

M4 × 15.5

(2)

Clamper

(1)

Part Names

Printed in China

T1114-1

F616441

Safety Precautions

Read before installation

 

 Read the Installation Instructions carefully to install the unit 
correctly and safely. 
Be sure to read the Safety Precautions in particular before 
installation.

 

After the installation is complete, perform test operation to confi rm 
that no abnormality is present.

 

We assume no responsibility for accidents or damages resulting 
from methods other than those described in the installation 
instructions or methods without using specifi ed parts. 
Malfunctions that occurred due to the unauthorised installation 
methods are not covered by the product warranty.

 

Read the installation instructions supplied with indoor units as well.

 WARNING

This symbol refers to a hazard or 
unsafe practice which can result in 
severe personal injury or death.

 CAUTION

This symbol refers to a hazard or unsafe 
practice which can result in personal injury 
or product or property damage.

 WARNING 

• Turn off the circuit breaker of 

the units before installation.

• Ask your dealer or 

professionals for installation 

and electric work.

• This receiver shall be installed 

in accordance with National 

Wiring Regulations.

• Securely connect and fi x the 

specifi ed cables for wiring.

• Do not allow the connection 

to be exposed to the external 
force of the cables.

• Choose an installation location 

that suffi ciently supports the 
weight of the receiver.

 CAUTION 

Do not use at the following locations.

• Location where condensation occurs

• Location where fl ammable gases, etc. may leak

• Location where corrosive gases, etc. may leak

• Location with lots of water or oil droplets 

(including machine oil)

• Location where voltage fl uctuation frequently 

occurs

• Location where there is a machine producing 

electromagnetic radiation

• Location where droplets of organic solvents 

spread

• Location where acidic or alkaline solutions or 

special sprays are frequently used

 

Do not operate with wet hands.

 

Do not wash with water.

g

n

i

t

t

e

S

 

g

n

i

t

n

u

o

M

Installation Precautions

Specifi cations

Dimensions

Wiring for the receiver

 

Wiring diagram

 

Type of wiring

Use cables of 0.5 to 1.25 mm

2

.

 

Total wire length: 

400 m or less 

(The wire length between indoor 
units should be 200 m or less.)

 

Number of connectable units

Remote controller and receiver: Max. 2, Indoor unit: Max. 8

Attention

R1 R2

R1 R2

R1 R2

1 2

1 2

1 2

Wired RC

Receiver

t

i

n

u

 

r

o

o

d

n

I

t

i

n

u

 

r

o

o

d

n

I

t

i

n

u

 

r

o

o

d

n

I

RC wiring

Receiver

*Wiring as shown below is prohibited.

1

2

R1

R2

Indoor unit

Terminals for RC wiring

Receiver

RC wiring (fi eld supply)
• No polarity

Model No.

CZ-RWSC3

Dimensions

(H) 120 mm × (W) 70 mm × (D) 20 mm

Weight

75 

g

Temperature/Humidity range

0 °C to 40 °C / 20 % to 80 % (No condensation)
*Indoor use only.

Power Source

DC16 V (supplied from indoor unit)

Installation when setting Main/Sub for the remote controller and the receiver

After installation, according to the "Main/Sub setting" in the "Setting" section, set one to [Main] and the other to [Sub].
Setting the wired remote controller to [Main] is recommended.

The remote controller and the receiver can be connected to any indoor unit for operation.

Note

 

Main/Sub setting

 

Address setting

Remove the top case of the receiver for setting.

Main/Sub setting

1  2  3  4

Switch

ON

OFF

 

Use this to set Main/Sub for the remote controller and the receiver.

 

Set one to [Main] and the other to [Sub].

 

Factory default: [Main]

 

It is recommended to set the wired remote controller to [Main].

B

U

S

N

I

A

M

b

u

S

/

n

i

a

M

Main/Sub switch position 

1 2 3 4

1 2 3 4

Address setting

 

When more than 1 receiver is installed in the same room, setting addresses prevents interference.

 

For how to change addresses of wireless remote controllers, see operating instructions of wireless remote controllers.

Wireless
remote controller
address display

Address

Address

Address

Address

Address

Address

Address

ALL

1

2

3

4

5

6

Address
switch position

Receiving is
possible at all
address positions.

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

Test operation

Preparation

:   Turn on the circuit breaker of units and then turn the power on. After the power is turned on, remote controller operation is ignored 

for approx. 1 minute because setting is being made. This is not malfunction. (Contents received while setting are disabled.)

1.  To start test operation, press and hold the emergency operation button for 10 seconds.
2.  The indication lamps (OPERATION, TIMER, STANDBY) blink during test operation.
3.  To fi nish test operation, press and hold the emergency operation button for 10 seconds.

Attention

 

Do not use this mode for purposes other than the test operation. 
(To prevent overload of the units)

 

Read the installation instructions supplied with the units.

 

Any of the Heat, Cool and Fan operations can only be performed.

 

Temperature cannot be changed.

 

The test operation mode is automatically turned off in 60 minutes. 
(To prevent continuous test operation) 

 

Outdoor units do not operate for approx. 3 minutes after the power is 
turned on or operation is stopped.

Self-diagnostics table and detected contents

 

The "Alarm Display" as shown in the table below expresses the alarm contents displayed when the wired remote controller is connected. For 
how to handle the alarms, see installation instructions of indoor units or technical guide.

r

e

v

i

e

c

e

r

 

e

h

t

 

n

o

 

p

m

a

l

 

n

o

i

t

a

c

i

d

n

I

s

t

n

e

t

n

o

c

 

d

e

t

c

e

t

e

D

Alarm Display

OPERATION

TIMER

STANDBY

Blinking

Communication error in the remote control circuit

E01–E03, E08–E14, E17, E18

Communication error either in the in/outdoor operation line or 
the sub-bus of the outdoor unit

E04–E07, E15, E16, E19–E31

Operation of indoor protection device

P01, P09–P14

Alternately

1

3

P

5

1

P

 

,

8

0

P

2

0

P

e

c

i

v

e

d

 

n

o

i

t

c

e

t

o

r

p

 

r

o

o

d

t

u

o

 

f

o

 

n

o

i

t

a

r

e

p

O

Alternately

1

1

F

0

1

F

 

,

3

0

F

1

0

F

r

o

t

s

i

m

r

e

h

t

 

r

o

o

d

n

i

 

e

h

t

 

n

i

 

r

o

r

r

E

Alternately

8

2

F

2

1

F

 

,

9

0

F

4

0

F

r

o

t

s

i

m

r

e

h

t

 

r

o

o

d

t

u

o

 

e

h

t

 

n

i

 

r

o

r

r

E

Alternately

9

2

F

M

O

R

P

E

E

 

r

o

o

d

n

i

 

e

h

t

 

n

i

 

r

o

r

r

E

Simultaneously

1

3

F

 

,

0

3

F

M

O

R

P

E

E

 

r

o

o

d

t

u

o

 

e

h

t

 

n

i

 

r

o

r

r

E

Simultaneously

1

3

H

1

0

H

r

o

s

s

e

r

p

m

o

c

 

e

h

t

 

o

t

 

d

e

t

a

l

e

r

 

r

o

r

r

E

9

0

L

5

0

L

 

,

3

0

L

1

0

L

s

g

n

i

t

t

e

s

 

r

o

o

d

n

i

 

n

i

 

r

o

r

r

E

Simultaneously

1

3

L

0

1

L

 

,

4

0

L

s

g

n

i

t

t

e

s

 

r

o

o

d

t

u

o

 

n

i

 

r

o

r

r

E

Simultaneously

Inconsistency in Air/Heat (Including an auto-temp setting 
for a model without auto-temp settings)

Alternately

Oil Alarm (Same as operation of outdoor protection device)

Alternately

Test operation

Simultaneously

: OFF  

: ON (Illuminated) 

: Blinking (0.5 seconds interval)

NOTICE

The English text is the original instructions. Other languages are translation of the 
original instructions.

1 2

1 2

R1 R2

R1 R2

R1 R2

R1 R2

RC wiring (fi eld supply)
• No polarity

Indoor unit

Indoor unit

Indoor unit

Indoor unit

1 2

1 2

R1 R2

Terminals for 

RC wiring

)

b

u

S

(

 

r

e

v

i

e

c

e

R

)

b

u

S

(

 

r

e

v

i

e

c

e

R

Wired RC (Main)

Wired RC (Main)

Indoor unit

 

Using 1 indoor unit

 

Using more than 1 indoor unit

RC wiring
(fi eld supply)
• No polarity

Installation 
example

70

4.4

4.4

2.

8

1

3.

8

1

83.5

20

120

34.4

8

5.4

Unit: mm

14

9.4

12

1

Remove the bottom case.

Attention

Mounting the bottom case

 

Tighten the screws securely until the screw 
heads touch the bottom case. 
(Otherwise, loose screw heads may hit the 
PCB and cause malfunction when mounting 
the top case.)

 

Do not over-tighten the screws. 
(The bottom case may be deformed, resulting 
in fall of the unit.)

Connecting the remote control wiring

 

Arrange the wires as shown in the illustration for 

 in step 

2

avoiding unnecessary wires being stored in the case. (Caught 
wires may destroy the PCB.)

 

Avoid wires touching parts on the PCB. 
(Caught wires may destroy the PCB.)

Flat-blade 
screwdriver

Bottom 
case

Insert the driver 

and slightly turn.

2

Mount to the wall.

e

p

y

t

 

d

e

d

d

e

b

m

E

e

p

y

t

 

d

e

s

o

p

x

E

Preparation

:  Make 2 holes for screws using a driver.

Preparation

:  Make 2 holes for screws using a driver.

1

3

2

Cut here with a 

nipper and remove 

the burr with 

a fi le.

Mount the top case.

 

Align the claws of 
the top case and 
then align the claws 
of the bottom case.

Mount the bottom case 
to the wall.

Connect the remote control wiring.

 

Arrange the wires along the groove of the case.

Wood screw (supplied)

Claw

Hole for screw

Wall to fi x the 
receiver

Claw (2 places)

Top case
(Back side)

Remove the coating. Approx. 6 mm

Remove the sheath. Approx. 150 mm

Make sure the wiring connection 
is in the correct direction.

Clamper

(supplied)

Pass through 

the hole.

Bottom case (Back side)

1

3

2

Avoid the wire 

being caught.

Mount the top case.

 

Align the claws of 
the top case and 
then align the claws 
of the bottom case.

Mount the bottom case to 
the wall.

 

Pass the wire through the hole 
in the centre of the bottom case.

Connect the remote control wiring.

Wood screw (supplied)

Claw (2 places)

Claw

Hole for screw

Terminal board

Bottom case (Back side)

Remove the coating.

Approx. 6 mm

Make sure the wiring connection 
is in the correct direction.

Top case
(Back side)

ENGLISH

欧州CZ-RWSC3据付(電気)工事説明書̲En.indd   1

欧州CZ-RWSC3据付(電気)工事説明書̲En.indd   1

2014/02/07   10:49:51

2014/02/07   10:49:51

Be careful not to connect cables to other terminals of indoor units (e.g. power source wiring
terminal). Malfunction may occur.
Do not bundle together with the power source wiring or store in the same metal tube. Operation
error may occur.
If noise is induced to the unit power supply, attach a noise filter.



For the RC wiring of field supply, please use insulated wires with sheath. 
The insulation thickness should be at least 1 mm.



Regulations on wire diameters differ from locality to locality. For field wiring 
rules, please refer to your LOCAL ELECTRICAL CODES before beginning.



You must ensure that installation complies with all relevant rules and regulations.

Summary of Contents for CZ-RWSC3

Page 1: ...vent overload of the units Read the installation instructions supplied with the units Any of the Heat Cool and Fan operations can only be performed Temperature cannot be changed The test operation mod...

Page 2: ...avo non rimanga impigliato Montare la copertura superiore Allineare le griffe della copertura superiore e poi allineare le griffe della copertura inferiore Montare la copertura inferiore sulla parete...

Page 3: ...tente no centro da placa inferior Ligue a cablagem do telecomando Parafuso para madeira fornecido Grampo 2 locais Grampo Orif cio para parafuso Placa de terminais Placa inferior parte posterior Retire...

Page 4: ...3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 1 10 2 OPERATION TIMER STANDBY 3 10 Heat Cool Fan 60 3 OPERATION TIMER STANDBY E01 E03 E08 E14 E17 E18 E04 E07 E15 E16 E19 E31 P01 P09 P14 P02 P08 P15 P3...

Page 5: ...able Instale la carcasa superior Alinee los cierres de la carcasa superior y a continuaci n haga lo mismo con la carcasa inferior Instale la carcasa inferior en la pared Introduzca el cable por el ori...

Page 6: ...en des Kabels Montage des oberen Geh uses Richten Sie die Greifer des oberen Geh uses und danach die Greifer des unteren Geh uses aus Montieren Sie das untere Geh use an die Wand F hren Sie das Kabel...

Page 7: ...sup rieur puis alignez les pinces du bo tier inf rieur Effectuez le montage mural du bo tier inf rieur Passez le c ble travers l orifice au milieu du bo tier inf rieur Connectez le c blage de la t l...

Reviews: