8.2
Mechanical Data
8.2.1 Control and Power Supply Unit
Mounting
:
free standing on a table top or mounted
in a 19" rack (requires 3HU (Height
Units) with bracket set LBB 3311/00.
Information about how to make the
necessary brackets for table flush moun-
ting is included (page 21).
Dimensions (h x w x d)
:
84 x 361 x 143 mm (with 5.5 mm feet);
3.4 x 14.2 x 5.6 in (with 0.22 in feet).
Weight
:
1.5 kg (3.3 lb)
8.2.2 Delegate/Chairman Units
Dimensions (w x d x h)
- without mic.
:
124 x 172 x 63 mm
(4.9 x 6.8 x 2.5 in)
- length of mic. from mounting
surface
:
/00 version :
313 mm (12.3 in)
/50 version :
488 mm (19.2 in)
- weigth
:
0.9 kg (2.0 lb)
8.3
General Data
8.3.1 System Environmental Conditions
Temperature range
Storage and transport
:
-20 to +70°C (-4 to +158°F)
Operational
:
+5 to +45°C (+41 to 113°F)
Ambient humidity
Operational
:
20% - 95% RH
Storage and transport
:
0% - 99% RH
Air pressure
:
600 mBar - 1100 mBar
Safety
:
acc. to EN 60065 and acc. to UL6500
(UL and cUL) for LBB 3310/00D)
Resistance to shock, vibration,
bump and transport
:
acc. to IEC68, 5G acceleration
EMC emission
:
acc. to EN 55103-1 and FCC rules
(part 15), class A