16
|
Axm ii / AxP
Configurable Motion Control Platform
1.3 axM II -
size 3
Overall dimensions and space required for installation
Technical specifications
(1)
AxM II 70.140.4
Units
Voltage supply
0 - 460
Vac 3 phase
Auxiliary feeeding voltage
22 - 30 / 4A
Vdc
Input current
140
Arms
Frequency
0 - 400
Hz
Nominal power
39
KW
Current output, axis < 100 rpm, S1
70
Arms
Current output, max speed, S1
61
Arms
Peak current
(2)
140
Arms
Power Losses total
(3)
1240
W
Maximum voltage output
Vin x 0,95
Vac
PWM
8 / 16
KHz
Efficiency at nominal power
96,4
%
Input form factor
0,9
Vac 3 phase
Maximum braking current
100% of peak current
- -
Cooling
2 fan 92x92x38 / flow rate: 560
m
3
/hour
Dimensions (WxHxD)
285,5 x 371 x 200
mm
(1) Test performed with full option control card and firmware 1.4.291 - (2) Peak rms current - (3) Including input rectifier losses