11
. COOLING SYSTEM
8
BR & M2 250 ENGINE
Connect the upper and lower hoses and secure
them with hose bands.
Connect the thermostatic switch wire and fan
motor wire couplers.
Connect the overflow tube and secure with the
tube clamp.
Fill the radiator with coolant. (
ð
3-9)
Connect the vent tube to the radiator filler.
After installation, check for coolant leaks.
.
Install the front upper cover.
Air Vent Tube
Radiator
Upper Hose
Overflow Tube
Lower Hose
Bolts
Thermostatic Switch Wire
Nuts
If you want to refill the coolant , the
following procedure must be checked.
1. Please make the radiator filler and the
air vent tube to be separated.
2. Then start the engine , filled in the coolant
till the coolant flowed out from the air
vent tube.