11
. COOLING SYSTEM
5
BR & M2 250
ENGINE
RADIATOR REMOVAL
Drain the coolant. (
ð
3-9)
Disconnect the air vent tube from the radiator
filler.
Remove the overflow tube clamp and
disconnect the overflow tube.
Loosen the hose band and disconnect the
upper hose and lower hose from the radiator.
Disconnect the thermostatic switch wire coupler.
Disconnect the fan motor wire coupler.
Air Vent Tube
Lower Hose
Upper Hose
Overflow Tube