background image

13

47

48

50

49

129

51

52

56

54

55

51

52

53

179

58

57

174

31

28

34

61

59

68

60

174

28

31

66

62

72

34

71

70

69

63

64
65
67

68

59

Helium-tight and korrosive gas models

2 Gas 

ballast 

13 Silencer 
14 Non-return 

valve 

28 Support 

stand 

31 O-ring 
34 Cover 
47 Valve 

spindle 

48 O-ring 
49 O-ring 
50 Valve 

housing 

51 Plate 

spring 

52 Screw 
53 O-ring 
54 Screw 
55 Insert 
56 Screw 
57 O-ring 
58 Centering 

sleeve 

59 Hole 
60 O-ring 
61 Sleeve 
62  Flushing gas connection 
63 O-ring 

64  Dosing valve unit 
65 O-ring 
66 Dosing 

insert 

67 Safety 

ring 

68 Valve 

housing 

69 O-ring 
70 Insert 
71 O-ring 
72 Intermediate 

piece 

129 Centering ring 
174 Screw connection 
179  Housing non-return valve 

Summary of Contents for DUO 120 A

Page 1: ...Rotary Vane Pumps PK 800 151 BE G 0311 UNO DUO 120 A Betriebsanleitung Operating Instructions...

Page 2: ...p And Checking The Operating Fluid 9 4 1 2 Operating Fluid F5 9 4 2 Switching The Pump ON And OFF 9 4 3 Gas Ballast Valve 10 4 3 1 Standard Model 10 4 3 2 Corrosive Gas Model 10 4 3 3 Magnetic control...

Page 3: ...conversions or modifications on the pump When returning the pump to us please note the shipping instructions in Section 7 1 1 For Your Orientation Instructions in the text Operating instructions Here...

Page 4: ...s manual is not permit ted without authorisation from PFEIFFER Improper use will cause any rights regarding liability and gua rantees to be forfeited Special Models Helium tight model Operating Fluid...

Page 5: ...with operating fluid before operating the first time included in a separate pack in the delivery consignment When transporting use only the eyebolts provided for the purpose When filled with operatin...

Page 6: ...ases on the connecting cable CAUTION CAUTION Switching parts list S3 Control switch S1 Pushbutton OFF S2 Pushbutton ON K1 Contactor F1 3 Motor fuse F5 Control fuse F8 Triggering Unit TMA 4 or TMA 4R H...

Page 7: ...nection The Rotary Vane Pumps UNO DUO 120 A have been designed so that they can be connected to a Rotation Speed and Operating Hours Monitor RCI 002 which is connected at connecting socket 45 For the...

Page 8: ...ing 132 Support washer 133 Radial shaft seal 134 Double supporting ring 135 Spacer 136 Oiler 138 O ring 168 O ring 169 Locking screw 180 Hose nozzle for inert gas inlet 169 180 122 132 133 135 126 128...

Page 9: ...in final vacuum operations In non stop operations check operating fluid daily otherwise whenever the pump is switched on 4 1 2 Operating Fluid F5 Only the synthetic operating fluid F5 may be used for...

Page 10: ...ushing gas connection It has a sliding sleeve which opens the valve when pushed towards the pump and shuts the valve when pushed away from the pump Fig 8 The dosing device is closed when the groove in...

Page 11: ...FEIFFER Service Oil leaking from the foot of the pump Radial shaft seal defective Request repair by PFEIFFER Service Pump doesn t start Ambient temperature 12 C Warm up pump Dirty pump stages Request...

Page 12: ...lowing precautions Always ensure the pump cannot be switched on when carrying out any work on the pump If necessary remove the pump from the system to carry out inspection work Only dismantle the pump...

Page 13: ...O ring 34 Cover 47 Valve spindle 48 O ring 49 O ring 50 Valve housing 51 Plate spring 52 Screw 53 O ring 54 Screw 55 Insert 56 Screw 57 O ring 58 Centering sleeve 59 Hole 60 O ring 61 Sleeve 62 Flush...

Page 14: ...dosing valve unit 64 Remove insert 70 Four borings have been provided on the front side for this operation Clean all parts Check O rings 65 and 69 for wear and replace if necessary Lightly oil O rings...

Page 15: ...time is kept to a minimum Have the pump repaired on the spot by our PFEIFFER Service Engineers Return the individual components to the manufacturer for repairs Replace individual components with a new...

Page 16: ...3360 2150 Noise development without gas ballast dB A 60 60 Operating fluid amount l 17 13 Max admissible operating temperature 1 C 90 90 Nominal rotation speed of pump at 50 Hz 1 min 965 965 at 60 Hz...

Page 17: ...comprehensive range of accessories can be found in section B of the Pfeiffer catalogue order no PA 800 066 PE to extend the application range of the pumps and protect the pump from wear when used unde...

Page 18: ...he repair and or service of vacuum components will only be carried out if a correctly completed declaration has been submitted Non completion will result in delay The manufacturer could refuse to acce...

Page 19: ...t the product specified below is in accordance with the provision of EU Machinery Directive 98 37 EEC Annex II A EU Electromagentic Compatibility Directive 89 336 EEC and EU Low Voltage Directive 73 2...

Page 20: ...81 3 32 259 011 Email pfeiffer hakuto co jp Korea Pfeiffer Vacuum Korea Ltd 703 Ho 853 1 Hankuk Mulru Dongchonri Suzi Eup 449 843 Yong in City Kyungkido Phone 82 31 266 0741 Fax 82 31 266 0747 Email s...

Reviews: