84
MP 250
L = 1.45 – 2.50 m
MP 350
L = 1.95 – 3.50 m
MP 480
L = 2.60 – 4.80 m
MP 625
L = 4.30 – 6.25 m
1.45
75.5
78.5
1.50
75.5
78.5
1.60
75.5
78.5
1.70
75.5
78.5
1.80
73.8
78.5
1.90
70.6
78.5
1.95
68.0
78.5
91.0
90.1
2.00
67.3
78.5
91.0
90.1
2.10
65.7
76.8
86.0
90.1
2.20
64.1
75.1
80.6
90.1
2.30
62.5
72.6
75.1
89.8
2.40
60.8
69.1
70.7
87.9
2.50
59.2
65.6
66.4
86.1
2.60
63.7
83.1
88.5
73.6
2.70
61.1
80.1
83.7
73.3
2.80
59.2
77.1
78.8
72.9
2.90
57.4
74.1
74.0
72.6
3.00
56.0
70.3
69.1
72.2
3.10
54.5
66.6
64.9
71.4
3.20
52.9
61.8
60.7
70.7
3.30
51.3
57.1
56.5
70.0
3.40
47.7
51.7
54.1
68.2
3.50
44.2
46.4
51.8
66.5
3.60
49.4
64.7
3.70
47.5
60.4
3.80
45.7
56.1
3.90
43.8
51.8
4.00
41.8
48.4
4.10
39.7
45.0
4.20
37.7
41.6
4.30
35.8
39.3
57.9
45.7
4.40
33.9
37.0
56.3
45.7
4.50
32.0
34.8
54.7
45.7
4.60
30.2
32.5
52.5
45.1
4.70
28.3
30.2
50.3
44.4
4.80
26.4
27.9
47.9
43.5
4.90
45.2
42.4
5.00
42.5
41.3
5.10
39.9
39.9
5.20
37.2
38.5
5.30
34.9
37.1
5.40
32.8
35.6
5.50
30.8
34.1
5.60
29.3
32.6
5.70
27.8
31.2
5.80
26.4
29.6
5.90
25.1
27.9
6.00
23.8
26.2
6.10
22.7
24.8
6.20
21.6
23.4
6.25
21.0
22.7
A18 Slab props
MULTIPROP 250, 350, 480, 625
Permissible prop load [kN] according to the type test
Extension
length [m]
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
MULTIPROP Props are classified according to official approval as follows:
MP 250 Class T 25
MP 350 Class R 35
MP 480 Class D 45
MP 625 Class D 60
Note:
To release the loads > 60 kN, we recommend using the HD Wingnut Spanner,
Item no. 022027.
When using PERI Slab Tables, the permissible load of the MULTIPROP MP 350
Prop is a minimum of 56 kN and a minimum of 36 kN for the MP 480 over the
entire extension length which is due to the clamping in the Table Swivel Head or
UNIPORTAL Head.
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
SKYDEKC AuV_ex_791458.indb 84
13.12.16 16:58
Summary of Contents for SKYDECK
Page 25: ...23 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 47: ...45 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 87: ...85 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...