![Peri SKYDECK Instructions For Assembly And Use Download Page 36](http://html1.mh-extra.com/html/peri/skydeck/skydeck_instructions-for-assembly-and-use_1529937036.webp)
34
9/12
x
y
13
x
y
9*
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
A6 Shuttering around columns
1 recessed panel
Maximum column dimensions
x = 55 cm, y = 138 cm.
Secure filler plates with nails!
Install Edge Beam SRT-2 150 vertically
(9) or Filler Timber SPH 150 (12).
During use, permissible loads must be
observed; see Tables: Fillers / Forming
around columns
Take into account the supporting
direction of the formlining.
Alternatively:
Install Edge Beam SRT-2 150 (9*) in a
suspended position. (Fig. A6.03)
Flatly position Filler Timber SPH or in-
stall timber (13) supplied by the contrac-
tor.
For 27 mm formlining: height of
timber = 47 mm.
Permissible widths of influence for
flat Filler Timber SPH, see Table A6.02.
Components
9
Edge Beam SRT-2 150
10
Edge Beam SRT-2 75
9*
Edge Beam SRT 150, suspended
10*
Edge Beam SRT 75, suspended
12
Filler Timber SPH
13
Timber
Fig. A6.02
Fig. A6.04
Fig. A6.03
Fig. A6.01
Width of Influence
SKYDEKC AuV_ex_791458.indb 34
13.12.16 16:56
Summary of Contents for SKYDECK
Page 25: ...23 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 47: ...45 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 87: ...85 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...