![Peri SKYDECK Instructions For Assembly And Use Download Page 83](http://html1.mh-extra.com/html/peri/skydeck/skydeck_instructions-for-assembly-and-use_1529937083.webp)
81
PEP Ergo B-300
L = 1.97 – 3.00 m
PEP Ergo B-350
L = 2.25 – 3.50 m
2.00
30.0
30.0
2.10
29.8
30.0
2.20
27.0
30.0
2.30
24.6
30.0
30.0
28.6
2.40
23.0
30.0
28.6
28.6
2.50
21.4
30.0
25.5
28.6
2.60
20.3
29.5
23.1
28.3
2.70
19.3
27.4
21.2
28.0
2.80
18.2
24.8
19.8
27.4
2.90
16.9
22.2
18.6
26.0
3.00
15.6
20.2
17.5
24.4
3.10
16.3
22.7
3.20
15.2
20.8
3.30
14.2
19.0
3.40
13.2
17.4
3.50
12.4
15.7
A18 Slab props
PEP Ergo B
Permissible prop load [kN] according to type test
E
xte
n
si
on
le
n
g
th
[
m
]
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Note:
■
PERI PEP Ergo B-300 and PEP Ergo B-350 Props meet
the load-bearing capacity requirements of Prop Class B
as stipulated in DIN EN 1065.
■
General Building Inspectorate Approval Z-8.311-934
issued by the German Institute for Building Technology
(DIBt).
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
SKYDEKC AuV_ex_791458.indb 81
13.12.16 16:58
Summary of Contents for SKYDECK
Page 25: ...23 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 47: ...45 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 87: ...85 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...