79
PEP 30-150
L = 0.96 – 1.50 m
PEP 30-250
L = 1.46 – 2.50 m
PEP 30-300
L = 1.71 – 3.00 m
PEP 30-350
L = 1.96 – 3.50 m
PEP 30-400
L = 2.21 – 4.00 m
1.00
36.4
36.4
1.10
36.4
36.4
1.20
36.4
36.4
1.30
35.9
36.4
1.40
35.3
36.4
1.50
34.5
36.4
42.9
42.9
1.60
42.9
42.9
1.70
42.9
42.9
1.80
42.1
42.9
42.9
42.9
1.90
39.7
42.9
42.9
42.9
2.00
37.9
42.9
42.9
42.9
45.5
45.5
2.10
36.4
42.9
42.9
42.9
45.5
45.5
2.20
35.5
42.9
42.9
42.9
45.5
45.5
2.30
34.3
41.5
42.9
42.9
45.5
45.5
41.5
41.5
2.40
33.1
38.7
42.7
42.9
45.5
45.5
41.5
41.5
2.50
31.0
35.9
41.1
42.9
45.5
45.5
41.5
41.5
2.60
40.0
42.9
45.5
45.5
41.5
41.5
2.70
38.5
42.9
45.5
45.5
41.5
41.5
2.80
36.9
41.6
45.5
45.5
41.5
41.5
2.90
34.2
38.3
45.0
45.5
41.5
41.5
3.00
31.3
34.8
43.6
45.5
41.5
41.5
3.10
41.4
44.2
41.5
41.5
3.20
38.7
42.1
41.5
41.5
3.30
36.1
38.7
41.5
41.5
3.40
33.3
35.7
41.5
41.5
3.50
30.7
32.5
41.5
41.5
3.60
41.5
41.5
3.70
41.3
41.5
3.80
38.5
41.3
3.90
35.9
38.1
4.00
33.2
34.9
A18 Slab props
PEP 30
Permissible prop load [kN] according to the type test
E
xte
n
si
on
le
n
g
th
[
m
]
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
Outer tube
bottom
Inner tube
bottom
All PEP 30 Props correspond to Class E
of DIN EN 1065, i. e. the permissible
load for all extension lengths is a mini-
mum of 30 kN.
When using PERI Slab Tables, the per-
missible load for all PEP 30 Props is a
minimum of 40 kN (PEP 30-150 = 35 kN)
over the entire extension lengths due to
the clamping in the Table Swivel Head
or UNIPORTAL Head.
SKYDECK Panel Slab Formwork
Instructions for Assembly and Use – Standard Configuration
SKYDEKC AuV_ex_791458.indb 79
13.12.16 16:58
Summary of Contents for SKYDECK
Page 25: ...23 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 47: ...45 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...
Page 87: ...85 SKYDECK Panel Slab Formwork Instructions for Assembly and Use Standard Configuration...