HOST MODE PROGRAMMING
85
PARAMETER CONTROL
RULES
Stop Phase Edge
(only for On Line 2
Input)
Must be
Leading
if
Extended Phase
Enable
ACK/NAK
Protocol
Not available if
Operating Mode Selection
On Line
.
Not available if
Scanner Cluster Topology Role
Slave
Synchronized
.
Quality Counters
Not available if
Operating Mode Selection
On Line
and
Automatic
.
Not available if
Scanner Cluster Topology Role
Slave
Synchronized
.
VERIFIER
Code Verifier
Not available if
Code Combination
Single Label
.
Not available if
Operating Mode Selection
On Line
and
Automatic
and
Continuous
.
READING SYSTEM LAYOUT
Device
Assignment
Must be
Master RS232 (Type A)
and
Slave RS232 (Type A)
if
Auxiliary Serial Port Data TX
Enable
.
Must be
Master RS232 (Type A)
and
Slave RS232 (Type A)
if
Auxiliary Serial Port Pass Through
Enable
.
DATA COMMUNICATION SETTING
Host Application
Protocol Type
Must be
Crisplant
if
Operating Mode Selection
On Line
.
Must be
Crisplant
if
On Line Options
Serial On Line
.
Must be
Crisplant
if
Main Port Communication Mode
Standard
.
Must be
Crisplant
if
Auxiliary Serial Port Pass Through
Enable
.
MAIN SERIAL PORT
Main Port
Communication
Mode
Must be
Standard if
Host Application Protocol Type
Standard
.
AUXILIARY SERIAL PORT
Data
Transmission
Must be = Disable if
Local Device Alternative Network Setting
Master RS232 (Type A)
or
Slave RS232 (Type A).
Pass Through
Must be = Disable if
Host Application Protocol Type
Standard
.
Must be = Disable if
Local Device Alternative Network Setting
=
Master RS232 (Type A)
or =
Slave RS232 (Type A).