HOST MODE PROGRAMMING
12
Using Short Parameter Description (Shortcut)
The '
Set Shortcut
' programming string (based on the short parameter description)
must have the following format:
SS
<space>
SHORTCUT
:
VALUE
<CR><LF>
Where:
SS
:
'Set Shortcut' command
SHORTCUT
:
Short Parameter Description (SHC)
VALUE
:
Parameter Value
After entering this command, the device responds with the proper reply message and
then waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with
the following message:
Y
<space>
VALUE
<CR><LF>
Where:
VALUE
:
Parameter Value
If programming contents are wrong (i.e. a typing error in the file) or due to a
transmission error, the device replies with the following message and programming
data will not be updated in this case:
N
<space>
ERRCODE
<CR><LF>
Where:
ERRCODE
:
Error Code (signed DEC value)
The complete Error Codes table is provided in the Paragraph 5.3.