HOST MODE PROGRAMMING
51
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
Header n. 6
(Siemens 3964)
/Comms
/SerMain/Line
/SRKHead6
541 3 Length:
1
Header n. 9
(Siemens 3964)
/Comms
/SerMain/Line
/SRKHead9
542 3 Length:
1
Header n. 10
(Siemens 3964)
/Comms
/SerMain/Line
/SRKHead10
539 3 Length:
1
Filler Character
(Siemens 3964)
/Comms
/SerMain/Line
/SRKFillChar
537 3 Length:
1
Filler Position
(Siemens 3964)
/Comms
/SerMain/Line
/SRKFillerPos
538
1
0 = Before Data
1 = After Data
AUXILIARY SERIAL PORT
Search For CBX
BM100 at Device
Startup
/Comms
/SerAux
/SearchForCBX
5247
1
0 = Disable
1 = Enable
Data TX
/Comms
/SerAux
/SerAux
511
1
0 = Disable
1 = Enable
Heartbeat /Comms
/SerAux
/HeartbeatEnA
5068
1
0 = Disable
1 = Enable
Unconditioned
2 = Enable
Conditioned
Pass Through
/Comms
/SerAux
/PTSource
512
1
0 = Disable
1 = Enable
AUXILIARY SERIAL PORT / HEARTBEAT
Timeout (s)
/Comms
/SerAux/HeartbeatA
/TimeOutA
5067
0
Range: 1 to 3600
Heartbeat Header
String
/Comms
/SerAux/HeartbeatA
/HeaderA
5063
3
Length: 0 to 128