HOST MODE PROGRAMMING
79
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
OSCILLATING
MIRROR:
Communication
Error
/Diagno
/Format/UserDefMsg
/OmCommErrMsg
5238 3
Length: 1 to 128
OSCILLATING
MIRROR: Reset
/Diagno
/Format/UserDefMsg
/OmResetMsg
5239 3
Length: 1 to 128
Reading Conditions
Controller:
Communication
Error
/Diagno
/Format/UserDefMsg
/DacCommErrMsg
5240 3
Length: 1 to 128
Focus Controller:
Communication
Error
/Diagno
/Format/UserDefMsg
/DpotzCommErrMsg
5241 3
Length: 1 to 128
Temperature
Sensor:
Communication
Error
/Diagno
/Format/UserDefMsg
/TempsCommErrMsg
5242 3
Length: 1 to 128
Laser Temperature
Sensor:
Communication
Error
/Diagno
/Format/UserDefMsg
/TempsANCommErrMs
g
5537 1
0 = Disable
1 = Enable
Temperature
Sensors Mismatch
Error
/Diagno
/Format/UserDefMsg
/TempsMismatchErrMs
g
5544 1
0 = Disable
1 = Enable
Low Temperature
Alarm
/Diagno
/Format/UserDefMsg
/LowTempsAlMsg
5545 1
0 = Disable
1 = Enable
High Temperature
Warning
/Diagno
/Format/UserDefMsg
/HighTempsWarnMsg
5546 1
0 = Disable
1 = Enable
Low Power Supply
Alarm
/Diagno
/Format/UserDefMsg
/LowPowerAlMsg
5547 1
0 = Disable
1 = Enable
Long Warm-up
Alarm
/Diagno
/Format/UserDefMsg
/LongWarmupAlMsg
5548 1
0 = Disable