HOST MODE PROGRAMMING
15
3.4 HOW TO ACCESS INSTALLER PARAMETERS
Set Right Parameter Description
The '
Set Right
' programming string allows the user to access some particular
parameters not available as standard user:
SR
<space>
L
<space>
PASSWORD
<CR><LF>
Where:
SR
:
'Set Right' command
L
:
Access Level Description
PASSWORD
: Password for the Level accessing
After entering this command, the device responds with the proper reply message and
then waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with
the following message:
Y
<space>
L
<CR><LF>
If programming contents are wrong (i.e. a typing error in the file) or due to a
transmission error, the device replies with the following message and programming
data will not be updated in this case:
N
<space>
ERRCODE
<CR><LF>
Where:
ERRCODE
:
Error Code (signed DEC value)
The complete Error Codes table is provided in the Paragraph 5.3.
NOTE
To set the INSTALLER use:
SR<space>1<space>STHD<CR><LF>