HOST MODE PROGRAMMING
52
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
Heartbeat Fields
Separator String
/Comms
/SerAux/HeartbeatA
/SeparatorA
5064
3
Length: 0 to 128
Counter Module
(Maximum Counter
Value)
/Comms
/SerAux/HeartbeatA
/CounterModA
5059
1
0 = Disable
1 = 10
2 = 100
3 = 1000
4 = 10000
5 = Custom
Custom Counter
Module
/Comms
/SerAux/HeartbeatA
/CustomCounterModA
5061
0
Length: 2 to 10000
Counter Starting
Value
/Comms
/SerAux/HeartbeatA
/CounterStartA
5060
0
Length: 0 to 9999
Counter Direction
/Comms
/SerAux/HeartbeatA
/CounterDirectionA
5058
1
0 = Up
1 = Down
System Diagnostics /Comms
/SerAux/HeartbeatA
/SysDiagA
5065
1
0 = Disable
1 = Enable
Network
Diagnostics
/Comms
/SerAux/HeartbeatA
/DevDiagA
5062
1
0 = Disable
1 = Enable
Heartbeat
Terminator String
/Comms
/SerAux/HeartbeatA
/TerminatorA
5066
3
Length: 0 to 128
AUXILIARY SERIAL PORT / PASS THROUGH OPTIONS
String Max Length
/Comms
/SerAux/PTOpt
/PTMaxDim
513
0
Range: 4 to 4096
Termination string
/Comms
/SerAux/PTOpt
/PTTerm
514
3
Length: 1 to 32
Pass Through on
ID-NET
/Comms
/SerAux/PTOpt
/PTSourceNet
5248
1
0 = Disable
1 = Enable