HOST MODE PROGRAMMING
19
3.6 EXAMPLES
- 1 -
Set
Minimum Label Length
parameter in
CODE LABEL SETTING #2
folder:
Path: /Codes/Code#2/MinLength
Shortcut: 3
Type: 0
(Integer)
Range:
0 to 60
Value: 4
The 'Set Parameter' programming string is:
SP<space>/Codes/Code#2/MinLength:4<CR><LF>
The 'Set Shortcut' programming string is:
SS<space>3#2:4<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>4<CR><LF>
- 2 -
Set
Operating Mode Selection
parameter in
OPERATING MODES
folder:
Path: /Operating/Selection
Shortcut: 31
Type: 1
(Enumeration)
Item List: 0 = On Line
1 = Automatic
3 = Test
4 = Continuous
Value:
1 (Entry 1
Automatic)
The 'Set Parameter' programming string is:
SP<space>/Operating/Selection:1<CR><LF>
The 'Set Shortcut' programming string is:
SS<space>31:1<CR><LF>