HOST MODE PROGRAMMING
43
4.6 DATA COMMUNICATION SETTING
PARAMETER COMPLETE
PATH
SHC
PT
VALUE
DATA COMMUNICATION SETTING
Host Application
Protocol Type
/Comms
/Application
84
1
0 = Standard
1 = Crisplant
DATA FORMAT
Header TX Start
/Comms
/OutForm
/HeadTx
505
1
0 = With Data
1 = After Reading Phase
On
Termination after
No Read Message
/Comms
/OutForm
/TermAfter
506
1
0 = Disable
1 = Enable
Message TX
selection (On Line
Operating Mode)
/Comms
/OutForm
/TxTrigSel
507
1
0 = On Decoding
1 = After Reading
Phase Off
2 = Delayed TX Line
Message TX
Selection
(Automatic
Operating Mode)
/Comms
/OutForm
/AutoTxTrig
543
1
0 = On Decoding
1 = After Reading
Phase Off
Physical Encoder
/Comms
/OutForm
/PhysicalEnc
5554
1
0 = Active Closed
1 = Active Open
Conveyor speed
(mm/sec)
/Comms
/OutForm
/ConvSpeed
5555
0
Range: 1 to 10000
Encoder Reference
Signal
/Comms
/OutForm
/EncRefSignal
5557
2
1 = Input 1
2 = Input 2
Encoder Step
(hundredths of mm)
/Comms
/OutForm
/EncoderStep
5556
0
Range: 1 to 10000
Distance (mm)
/Comms
/OutForm
/Distance
5558
0
Range: 100 to 20000
Format Type
/Comms
/OutForm
/FormatType
330
1
0 = Standard
1 = Advanced