HOST MODE PROGRAMMING
21
After enter the programming string, the reader responds with the message:
Y<space>6<space> 484541444552<CR><LF>
- 5 -
Get value of Digital Output 2
Activation Event
parameter in
DIGITAL OUTPUT LINES
SETTING
folder:
Path: /IO/Out/Out1/Active
Shortcut: 24
Type: 1
(Enumeration)
Current value: 2 (Entry 2
Partial Read)
The 'Get Parameter' programming string is:
GP<space>/IO/Out/Out1/Active<CR><LF>
The 'Get Shortcut' programming string is:
GS<space>24<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>2<CR><LF>
- 6 -
Get value of
No Read String
parameter in
CODE DEFINITION
folder:
Path: /Codes/NoReadStr
Shortcut: 9
Type:
3 (Binary String)
Current value: Empty string
The 'Get Parameter' programming string is:
GP<space>/Codes/NoReadStr<CR><LF>
The 'Get Shortcut' programming string is:
GS<space>9<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>0<CR><LF>