C
OPYRIGHT
& T
RADEMARKS
Specifications are subject to change without notice. Copyright © 2020 Pepwave Ltd. All Rights Reserved. Pepwave and the Pepwave logo
are trademarks of Peplink. Other brands or products mentioned may be trademarks or registered trademarks of their respective owners.
Distance / Time
Convertor
This slider and text entry field can be used to interactively set slot time.
Slot Time
This field provides the option to modify the unit wait time before your access point
transmits. The default value is
9
μs
.
ACK Timeout
Set the wait time to receive an acknowledgement packet before retransmitting. The
default value is
48
μs
.
Frame
Aggregation
With this feature enabled, throughput will be increased by sending two or more data
frames in a single transmission.
Aggregation
Length
This field is only available when
Frame Aggregation
is enabled. It specifies the frame
length for frame aggregation. By default, it is set to
50000
.
Max number of
Clients
Enter the maximum clients that can simultaneously connect to your access point or set
the value to
0
to allow unlimited clients.
Client Signal
Strength
Threshold
This field determines the minimum acceptable client signal strength, specified in
megawatts. If client signal strength does not meet this minimum, the client will not be
allowed to connect.
Advanced Features
Discover Nearby
Check this box to enable network discovery. Note that setting
Channel
to
Auto
will
activate this feature automatically.