CP302
CMOS Setup
ID 21112, Rev. 05
Page 4 - 33
®
PEP Modular Computers GmbH
Memory Parity Error at ...
Indicates a memory parity error at a specific location. You can use this location along
with the memory map for your system to find and replace the bad memory chips.
Memory Size Has Changed Since Last Boot
Memory has been added or removed since the last boot. In EISA mode use the
configuration utility to reconfigure the memory configuration. In ISA mode enter “Setup”
and enter the new memory size into the memory fields.
Memory Verify Error at ...
Indicates an error verifying a value already written to memory. Use the location along
with your system's memory map to locate the bad chip.
Offending Address not Found
This message is used in conjunction with the “I/O Channel Check” and “RAM Parity
Error” messages whenever the segment that has caused the problem cannot be
isolated.
Offending Segment
This message is used in conjunction with the “I/O Channel Check” and “RAM Parity
Error” messages whenever the segment that has caused the problem has been
isolated.
Press a Key to Reboot
This message appears at the bottom of the screen when an error occurs that requires
you to reboot. Press any key to reboot the system.
Press “F1” to Disable NMI, “F2” to Reboot
When the BIOS detects a non-maskable interrupt condition during boot, you can disable
the NMI and continue to boot, or you can reboot the system with the NMI enabled.
RAM Parity Error - Checking for Segment ...
Indicates a parity error in the random access memory.
Should Be Empty But EISA Board Found - Please Run EISA Configuration Utility
A valid board ID was found in a slot that was configured as having no board ID.
$
$
Note:
When this error appears, the system boots in ISA mode so that
you can run the EISA configuration utility.