64
Table of Error Code (Digital adjustment)
When adjustment error is occurred, below screen will be displayed.
[Table of Error Code for Digital adjustment]
AA - BB - CC - DD - EE
AA:
00
Initialize
02
CCD Information
04
Pre-Process Gain
05
ISO Base Gain
06
Bad Pixel Defection
BB-CC: Initialize (AA=00)
BB-CC: ISO Gain (AA=05)
DD-EE:
01-01
Reading setting file
01-01
Mode dial is not switched
01-00
02-01
Camera - PC connection
01-02
01-01
02-02
Camera - PC connection
01-03
01-02
02-03
Acquisition of camera status
01-04
02-01
Can not access to file
02-04
Acquisition of camera information
01-05
Mode dial is not "M" mode
05-01
03-01
CCD file open
01-07
Not setting multi segment metering
06-01
03-02
CCD file size not correct
01-09
Not setting to allowing to release at M position
07-00
03-04
CCD file data is not correct
01-10
SR SW is not set to OFF
07-01
05-05
Missing setting file, light calibration file
03-01
Can not set shutter speed
08-00
Out of range (too low )
06-01
DSP version is not the same
03-02
Can not set diaphragm
08-01
Out of range (too high)
06-02
CPU version is not the same
03-03
Can not set ISO
08-02
White scratch: many of high level pixels
07-01
Can not read ISOgain adjustment
03-04
Can not set exposure compensation
08-03
White scratch: cannot correct (continuity scratch)
07-02
Can not read PPG adjustment value
03-05
Can not set WB
08-04
Black scratch: cannot correct (continuity scratch)
03-06
Can not metering
08-05
Cannot correct scratch
BB-CC: Pre-Process Gain (AA=04)
03-07
Can not acquisition of AE information
08-06
HW scratch correct failure
01-01
Mode dial is not switched
04-01
08-07
Can not set power control
01-02
10-01
08-08
AFE calibration NG
01-03
04-02
08-09
Can not acquisition of power control value
01-04
10-02
08-10
light compensation RGG ratio
01-05
Mode dial is not "M" mode
08-01
09-00
FE version is not correct
01-07
Not setting multi segment metering
14-01
09-01
Skipped previous process
01-09
Not setting to allowing to release at M position
17-01
Can not set adjusted value
09-02
Trying to adjust master body
01-10
SR SW is not set to OFF
17-02
Not switch to writing mode for adjusted value
03-01
Can not set shutter speed
17-03
Can not write adjusted value
03-02
Can not set diaphragm
03-03
Can not set ISO
BB-CC: Bad Pixel Defection (AA=06)
03-04
Can not set exposure compensation
01-01
Mode dial is not switched
03-05
Can not set WB
01-02
03-06
Can not metering
01-03
03-07
Can not acquisition of AE information
01-04
05-01
01-05
Mode dial is not "M" mode
08-01
01-07
Not setting multi segment metering
14-01
01-09
Not setting to allowing to release at M position
05-02
01-10
SR SW is not set to OFF
08-02
02-02
Can not set dummy lens
14-02
03-01
Can not set shutter speed
07-01
03-02
Can not set diaphragm
12-01
03-03
Can not set ISO
20-01
Can not set adjusted value
03-04
Can not set exposure compensation
20-02
Not switch to writing mode for adjusted value
03-05
Can not set WB
20-03
Can not write adjusted value
03-06
Can not metering
03-07
Can not acquisition of AE information
08-08
Can not write adjusted value
BB-CC: Error item
Can not setting camera
Can not set PPG gain value
Can not set CCD gain value
Can not set CCD gain value
CCD output value is not correct
Connection error for USB or No power of Camera
Can not transfer USB command correctly
CCD output value is not correct
DD-EE: Error content
AA: Adjusting item
Can not setting camera
Can not set PPG gain value
Can not setting camera
Initialize check
CCD data display
WB Adjustment
ISO Gain adjustment
CCD pixel compensation adjustment